Operation Manual
Shenzhen Dericam Technology Co .,Limited www.dericam.net
35
Attention:
workday and weekend field only used in working days rest days mode,
week0 ~ week 6 field only used in all week mode,and start time must be less
then end time .
T he calculation method of these start and end time field are:
If time is 0 hour 0 miniute, it will be set to “ none ” ,
Other cases according to the following formula :
strart-time = start-hour * 4 + start-minute number
end-time = end-hour * 4 + end-minute number - 1 ;
One minute is split to four t ime period : 0(number is 0), 15(number is 1),
30(number is 2) and 45(number is 3).
For example:
I f s pecify a start time of 8:30 , then start-time = 8*4+2=34,
I f s pecify a end time of 8:30 , then end-time = =8*4+2-1=33
Note
Example / cgi-bin/hi3510/param.cgi ? cmd=setschedule&-type=event&-ename=md&-etm
=1&-workday=0 ~33 &-weekend=none
/ cgi-bin/hi3510/param.cgi ? cmd=setschedule&-type=event&-ename=md&-etm
=2
param.cgi?cmd=getalarmserverattr
param.cgi?cmd=getalarmserverattr
param.cgi?cmd=getalarmserverattr
param.cgi?cmd=getalarmserverattr
Function
To get alarm server parameters
Authority
admin
Syntax / cgi-bin/hi3510/param.cgi [ ?cmd= g et alarmserverattr]
parameters None
Return Value as_server S erver address
as_port S erver port (1-65535)
as_username username
as_password password
Note None
Example / cgi-bin/hi3510/param.cgi?cmd= g et alarmserverattr