Operation Manual

Shenzhen Dericam Technology Co .,Limited www.dericam.net
29
m3 _h R egion 3 height
m3 _sensitivity R egion 3 sensitivity
m3 _threshold
R eserved, unused
m4 _enable T he fourth m otion detectio n region:
0: disable
1: enable
m4 _x R e gion 4 abscissa
m4 _y R egion 4 Ordinate
m4 _w Region 4 width
m4 _h R egion 4 height
m4 _sensitivity R egion 4 sensitivity
m4 _threshold
R eserved, unused
Note
T he region c oordinate , width and height are based the max resolution of this
device.
Example / cgi-bin/hi3510/param.cgi?cmd= getmdattr
param.cgi?cmd=setmdattr
param.cgi?cmd=setmdattr
param.cgi?cmd=setmdattr
param.cgi?cmd=setmdattr
Function To set m otion detection parameters
Authority admin
Syntax / cgi-bin/hi3510/param.cgi [?cmd= setmdattr & -enable =& -s =& -name =& -x =& - y=
& - w=& - h=]
parameters
enable m otion detection function:
0: disable
1: enable
s sensitivity: range [0 ~ 100]
name A larm region : range[1 ~ 4]
x m otion detection re gion abscissa
y m otion detection re gion Ordinate
w m otion detection re gion width
h m otion detection re gion height
Return Value
Success: contain Success
Failure: contain Error
Note
T he region c oordinate , width and height are based the max resolution of this
device.
Example /cgi-bin/hi3510/param.cgi?cmd=setmdattr&-enable=1&-s=50&-name= 1 &-x= 0
&-y= 0 &-w= 60 &-h= 60