Operation Manual
Shenzhen Dericam Technology Co .,Limited www.dericam.net
25
param.cgi?cmd=g
param.cgi?cmd=g
param.cgi?cmd=g
param.cgi?cmd=g etptzcomattr
etptzcomattr
etptzcomattr
etptzcomattr
Function
To get PTZ parameters
Authority admin
Syntax
/ cgi-bin/hi3510/param.cgi [ ?cmd=getptzcomattr ]
parameters None
Return Value protocal P rotocol type:
0: PELCO-D
1: PELCO-P
address A ddress code ( 0~255 )
baud B aud rate
databit D ata width
stopbit S top bit
check Parity:
0: None
1: odd parity
2: even parity
3: mark
4: space
Note Some device does not support this attribute , reference to Appendix I:
Definition of device type
Example / cgi-bin/hi3510/ param.cgi?cmd= getptzcomattr
param.cgi?cmd=
param.cgi?cmd=
param.cgi?cmd=
param.cgi?cmd= s
s
s
s etptzcomattr
etptzcomattr
etptzcomattr
etptzcomattr
Function To set PTZ parameters
Authority admin
Syntax
/ cgi-bin/hi3510/ param.cgi[?cmd= setptzcomattr & -protocal =& -address =& -baud
=& -databit =& -stopbit =& -check =]
parameters
protocal P rotocol type:
0: PELCO-D
1: PELCO-P
address A ddress code: 0~255
baud B aud rate:
1200 、 2400 、 4800 、 9600 、 19200 、 38400 、
57600
databit D ata width: 7 or 8