Specifications

53
No
Function
Command
RW
Min
Max
Default
Step
Parameter
16V
Color Temp
TMP
RW
0
2
Source
Specific
1
Valid only when Display
Mode = User
0:Warm
1:Normal
2:Cold
17V
Contrast
CON
RW
0
100
50
1
Valid only when Display
Mode = User
18V
Current Source
SRC
RW
0
13
0
1
0:VGA1
5:HDMI-1
6:HDMI-2
10:Component
12:Video
13:S-Video
21V
Digital Zoom
DZM
RW
-10
10
0
1
-10~10
27V
Error Condition
ERR
R
n/a
n/a
n/a
n/a
0:No error
1:Lamp not lit after 5 At-
tempts
3:Lamp went out unexpect-
edly
4:Fan failure
5:Over- heating
8:DMD error
9:Color wheel
28V
Factory Reset
RST
W
n/a
1
1
1
1:reset
32V
Freeze Screen
FRZ
RW
0
1
0
1
0:Disable
34V
Gamma
GTB
RW
0
5
Source
Specific
1
Valid only when Display
Mode = User
0:1.8
1:2.0
2:2.2
3:2.4
4:B&W
5:Linear
40V
Horz. Position
HPS
RW
x
x
0
1
RGB source only
(HPS?) to get range
45V
Lamp Hours in High
Power Mode
LMO
R
0
9999
Displays the number of
hours that the current lamp
has run in High Power
(Normal) mode.
46V
Lamp Hours in Low
Power Mode
LME
R
0
9999
Displays the number of
hours that the current lamp
has run in Low Power (Eco)
mode.
47V
Lamp Life
LIF
R
n/a
4000
240W lamp life 4000
49V
Lamp Resets (Total
number)
LMR
R
0
9999
0
1
62V
Lamp Low Power
IPM
RW
0
1
0
1
1=ECO, 0=Normal