Operator`s manual

8
For example: End = 14:30 -> _ _ :_ _
The computer uses a 24 hour clock. Therefore, the completion time will be 2:30 PM.
6. Pressing the Delay Start
D
key again shows the actual time (Now).
Pressing the key additional times will cycle through the other parameters. Press the Escape
ESC
key to stop
the function.
Running A Delay Start Program:
1. Select the desired program number (See previous section on RUNNING A PROGRAM)
2. Press the Delay Start
D
key to display the delay days.
3. Press the green start
S
key to start the delay timer.
- The corresponding LED will also light to indicate the Delay Start is selected.
- If the program run time is longer than the specified delay time the furnace will skip the delay and start the program
immediately.
LINKING PROGRAMS
Programs can automatically run in sequence by using the Linking feature. With this method, a 6 stage (12 segment)
program can be run automatically. Additional programs can also be linked as each program is completed.
Running Linked Programs:
1. Press the green Start
S
key with the first program to be run. The furnace will start operation.
2. Use the digit keys (1,2,...,9) to enter the next program number to be run followed by the ENTER key. The
furnace will now run the first program followed automatically by the second. The program cycle time on the
display will be the combination of the two programs. The display will alternately show the first program number
and then the second program number.