Specifications

389
16.2.2 Detailed Function Specifications
Syntax: CALL "SYSTEM.FN3" 0 VERSION$
Description:
This function returns the SYSTEM.FN3 library version in VER-
SION$.
Parameter:
(None)
Returned value: VERSION$ Version which is fixed to 7 characters
Syntax: CALL "SYSTEM.FN3" 1 PARA%,DATA%
Description:
This function reads numeric data (DATA%) from the system menu
item specified by
PARA%.
Parameter: PARA% Item number of the system menu
Returned value: DATA% Numeric data read from the specified system menu item
System menu items list:
*1
R/W: Read and write possible
RO: Read only
Function #0: Get SYSTEM.FN3 version
Function #1: Read numeric data from System Mode settings
Item number
(
PARA%)
System menu item
Attribute
*1
DATA%, numeric data of the
system menu item
Initial value
1
Shift key mode R/W 0: Nonlock
1: Onetime
0
2
Assignment to M1 key R/W 0: None
1: Enter key
2: Trigger switch
3: Shift key
4: Backlight on/off function key
0
3
Assignment to M2 key R/W Same as above. 0
4
Assignment to M3 key R/W Same as above. 2
5
Assignment to M4 key R/W Same as above. 2
6
Black-and-white inverted label
reading function
R/W 0: OFF
1: ON
0
7
Reserved for system
8
Decode level R/W 1 to 9 4
9
Minimum number of digits to be
read for ITF
R/W 2 to 20 4
10
Minimum number of digits to be
read for STF
R/W 1 to 20 2