Specifications

Chapter 16. Extended Functions
393
*1
R/W: Read and write possible
RO: Read only
Note: Items #41 through #46 take effect only when the LAN communica-
tions software is installed to the BHT.
.syScnMark 38 Scanning range
marker
(BHT-100Q)
R/W 0 Normal mode (Driven by the
trigger switch)
0
1 Fixed to ON
2 Fixed to OFF
Scanning range
marker
(BHT-100B)
R/W 0 Normal mode (Driven by the
trigger switch)
0
1 Fixed to OFF
.syVwFindr 39 View finder
(BHT-100Q only)
R/W .syVFOff 0 OFF 0
.syVFOn 1 ON
.syOptData 40 Option data
(BHT-100Q only)
R/W .syODOff 0 OFF 0
.syODOn 1 ON
.syLkCnt 41 Retries of establish
link command
R/W 0 to 32767 5
.syLkIntv 42 Intervals between
retries of establish link
command
R/W 1 to 32767 (100 ms to 3276.7 sec.) 5
(500 ms)
.syUlkCnt 43 Retries of release link
command
R/W 0 to 32767 5
.syUlkIntv 44 Intervals between
retries of release link
command
R/W 1 to 32767 (100 ms to 3276.7 sec) 5
(500 ms)
.syUlkTmr 45 Link release period R/W 0 to 32767 (sec.) 30
.syDvSpd 46 Transmission speed
between the BHT and
LAN-support CU
R/W 5: 115200 bps 5
(115200
bps)
Item number
(PARA%)
System menu item
Attribute
*1
DATA%, numeric data of
the system menu item
Initial
value