Specifications
Chapter 8. Files
133
8.3 Bar Code Device
8.3.1 Overview
■ Opening the Bar Code Device by OPEN "BAR:" Statement
BHT-100Q
The OPEN "BAR:" statement opens the bar code device. In this statement, you may spec-
ify the following code types available in the BHT. The BHT can handle one of them or their
combination.
*
1
Reading wide bars
EAN-13 and UPC-A bar codes may be wider than the readable area of the reading win-
dow.
Such wider bars can be read by long-distance scanning. Pull the reading window away
from the bar code so that the entire bar code comes into the illumination range. (No dou-
ble-touch reading feature is supported.)
*
2
Specifying Code 128 makes it possible to read not only Code 128 but also EAN-128.
Available Code Types Default Settings
2D codes
QR Code All of Model 1, Model 2, and MicroQR sup-
ported.
No code version specified.
No split code scanning mode.
PDF417 No option required.
MaxiCode No option required.
Data Matrix No option required.
Bar codes
Universal product codes EAN-13*
1
EAN-8
UPC-A*
1
UPC-E
No national flag specified.
Interleaved 2of5 (ITF) No read data length specified.
No check digit.
Codabar (NW-7) No read data length specified.
No check digit.
No start/stop character.
Code 39 No read data length specified.
No check digit.
Code 128 (EAN-128)*
2
No read data length specified.