OPERATION MANUAL OFFICE PRO 36 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS. DENSO SALES CALIFORNIA, INC. 3900 Via Oro Avenue Long Beach CA 90810-1868 800-264-9573 / 310-834-6352 www.movincool.com DSCA P/N: LA484007-1810 First Issue: March 2005 Printed in the U.S.A.
LIMITED WARRANTY DENSO SALES CALIFORNIA, INC. (“DENSO”) warrants its MOVINCOOL Products only to the extent stated in its official written warranties.
TABLE OF CONTENTS FOREWORD ............................................................................................ 1 Definition of Terms ........................................................................... 1 GENERAL WARNINGS & CAUTIONS .................................................... 1 INVENTORY ............................................................................................. 2 INSTALLATION ........................................................................................
FOREWORD Congratulations on purchasing the MovinCool portable air conditioner. This manual explains how to assemble, install and operate the MovinCool Office Pro 36 portable air conditioning unit. Please read this operation manual thoroughly to familiarize yourself with the features of the unit and to ensure years of reliable operation. You may also find it useful to keep this operation manual on hand for reference. Components and/or procedures are subject to change without prior notice.
INVENTORY After unpacking your MovinCool unit, please check to make sure you have the following items: • Office Pro 36 MovinCool Unit (1) • Operation Manual/Warranty Card (1) NOTE: If any of these items were not included in the box or appear damaged, please contact your MovinCool reseller for replacement. 36 OPERATION MANUAL/ WARRANTY CARD INSTALLATION Choosing an Installation Site CAUTION: Following are some precautions to consider before choosing your installation site.
Moving the Unit Unlock the casters and push the MovinCool unit, using the side handles, to a flat, level surface and set the casters back to the LOCKED position. FRONT AND BACK HANDLES UNLOCKED LOCKED Plugging in the Unit • Check the prongs and surface of the power cord plug for dust/dirt. If dust and/or dirt are present, wipe off with a clean, dry cloth. • Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller for repair.
FEATURES OP36 Features • • • • • • • • An electronic control panel which allows the user to control the unit’s operation easily. Dual fan speeds (either High or Low) in both COOL and Fan Only modes. A digital display that indicates the Temperature SET POINT (either Fahrenheit or Celsius) in which the COOL Mode will operate. This is also the temperature the unit will try to maintain. The Temperature SET POINT can be adjusted by the SET TEMP buttons (▼/▲).
7 7. Temperature Scale LED - Illuminates to indicate the current temperatures being displayed are either in °C or °F; also used to display the clock when programming. 8. AM/PM LED - Illuminates to indicate AM or PM time of day. 9. Program RUN Button - Activates/deactivates a program. 10. Program SET Button - Allows the user to program the unit or check the current program. 11. START TIME LED, END TIME LED, SET CLOCK LED - Illuminates to indicate the current step that is being programmed into the unit.
How to Set a Program ➀ Setting a START TIME Press the Program SET button. The Program SET button and START TIME LEDs will illuminate. Press the HRS and MIN buttons to set the START TIME. ➁ Setting an END TIME Press the Program SET button until the END TIME LED illuminates. Press the HRS and MIN buttons to set the END TIME. ➂ Setting the CLOCK TIME Press the Program SET button until the SET ET CLOCK LED illuminates. Press the HRS and MIN buttons to set the current clock time into the unit.
Operating Modes Office Pro 36 operates in 2 modes, FAN Only and COOL. When in FAN Only mode, the unit circulates the surrounding air. When in COOL mode, the compressor is operational and cool air is circulated. • COOL Mode Office Pro 36 will operate in FAN Only mode for approximately 120 seconds before the compressor engages. (Time delay setting is 120 ±15 seconds.) • Temperature Control • The room temperature thermistor allows the unit to switch automatically between COOL and FAN Only modes.
Drain Pump (Optional) A drain pump allows continuous operation and eliminates the need for drain tanks. • When the water collects to level (A) in the pump reservoir, the drain pump begins to operate and discharges the water. • When the water level drops below level (B), the drain pump will stop. NOTE: • If for any reason the water level exceeds that of level (A) in the pump reservoir, an overflow Drain Switch will stop the compressor operation. • If the Fan Mode Control DIP Switch (see pg.
Cleaning Method ➀ Remove dust from the element with a vacuum cleaner, or rinse in cold or lukewarm water. If the element is extremely dirty, wash FILTER with a neutral detergent. ➁ After the element has been cleaned, rinse with clean running water, allow to dry, then reinstall. In-Season/Off-Season Inspection & Maintenance ■ In-Season ■ Check the prongs and surface of the power cord plug for dust and/or dirt. If dust and/or dirt are present, wipe off with a clean, dry cloth.
Check the following points before calling a qualified technician.
TECHNICAL SPECIFICATIONS ITEM/FEATURES OFFICE PRO 36 Rating Conditions dry bulb wet bulb humidity 95º F (35º C) 83º F (28.2º C) 60% Specifications power frequency line voltage power consumption current consumption power factor starting current power wiring 60Hz single phase 208/230V 4.4 Kw 19.
LIMITED WARRANTY DENSO SALES CALIFORNIA, INC. (“DENSO”) warrants its MOVINCOOL Products only to the extent stated in its official written warranties.
OPERATION MANUAL OFFICE PRO 36 READ THIS MANUAL CAREFULLY FOR INSTRUCTIONS ON CORRECT INSTALLATION AND USAGE, AND READ ALL SAFEGUARDS. DENSO SALES CALIFORNIA, INC. 3900 Via Oro Avenue Long Beach CA 90810-1868 800-264-9573 / 310-834-6352 www.movincool.com DSCA P/N: LA484007-1810 First Issue: March 2005 Printed in the U.S.A.