Specifications
[Issue No.] GOT-A-0064-C [Page] 8/39
[Title] List of Valid Devices Applicable for GOT2000 Series
[Date of Issue] Ver. C: February 2015 (First Edition: September 2013)
[Relevant Models] GOT2000 Series
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
TECHNICAL BULLETIN
1) Cable connection diagram for a barcode reader manufactured by OMRON Corporation
The following shows connection cables that must be produced by the user.
Maximum cable length: confirm with the barcode reader manufacturer.
Barcode reader
Cable connection and signal direction
GOT
Signal
direction
Signal
name
Pin No. Pin No. Signal name
Internal
connection
FG 1
1 CD
SD(TXD) *1 2 2 RD(RXD)
RD(RXD) *1 3 3 SD(TXD)
RS(RTS) 4 4 ER(DTR)
CS(CTS) 5 5 SG
─ 6 6 DR(DSR)
─ 7 7 RS(RTS)
─ 8 8 CS(CTS)
SG 9 9 ─
*1: A dedicated cable, V509-W012 (cross cable), is used between the barcode reader and the cables mentioned
above. Even if the signal name for cable connection is SD-SD or RD-RD, the communication can be performed
with no problem.
3.2.3 System equipment (3)
GOT
Attached cable
Wi
r
eless
barcode reader
Barcode reader
dedicated communication unit
Manufacturer
Wireless barcode
reader
Barcode reader
dedicated
communication unit
Attached cable
Nippon Systems
Development Co.,Ltd.
AC-812-000-D1
PDC-812-400-00+
PDC-812-300-D1
Included with a barcode
reader
Included with a barcode
reader