(3) Paper jam
For the paper jam, remove the paper, and then execute the printing process again by using the GOT.
When the printing process does not start after the above actions, execute any of the following methods.
(a) Press the cancel button on the printer to stop the printing process, and then execute the printing process
again by using the GOT.
(b) Disconnect and connect the cable of the printer, and then turn on the printer again. (The printing process
starts again automatically.)
(d) Press the OK button on the printer to stop the printing process. Then execute the printing process again by
using the GOT.
(e) Press the cancel button on the printer. (The printing process starts again automatically.)
(4) Others
For some printers, the print enable/disable status notification signal (GS258.b3) may turn on before the
preparations for printing are not completed.
Check the preparations for printing and then execute the printing process.
14.2 Serial printer
You can use a serial printer by connecting the printer to the built-in RS-232 interface, or by mounting the
GT15-RS2-9P on the GOT.
To use a serial printer, write the package data to the GOT using the screen design software of
GT Works3
Version1.105K or later
.
The GOT supports printer control code ESC/P24-J84.
(Compatible Product)
Manufacturer Model Available hard copy size Reference
NADA ELECTRONICS, LTD.
TP-642EG *1 QVGA, VGA *2
Refer to (1) below.
TP-1728G *1 QVGA, VGA, SVGA, XGA
SEIKO EPSON CORPORATION VP-700U QVGA, VGA, SVGA Refer to (2) below.
*1: TP-642EG and TP-1728G only support the hard copy function.
*2: Since the printing width of the data is larger than the paper width, set the printer to “Do not print unprintable area.” or “Reduce and print