Specifications
[Issue No.] GOT-A-0064-C [Page] 33/39
[Title] List of Valid Devices Applicable for GOT2000 Series
[Date of Issue] Ver. C: February 2015 (First Edition: September 2013)
[Relevant Models] GOT2000 Series
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
TECHNICAL BULLETIN
9.3 How to read data by an RFID controller
Please refer to the followings for the data transfer format (header/terminator settings and others) that can be
used in the GOT or the setting method to read data by an RFID controller.
(a) Data transfer format (header/terminator settings and others) that can be used in the GOT.
(b) Setting to connect an RFID controller to the GOT. ([Peripheral Setting] on GT Designer3(GOT2000))
(c) Setting to write the data, read by an RFID controller, to the PLC CPU. ([Detail Setting] in the [Bar Code]
dialog box on GT Designer3(GOT2000))
Refer to the following.
➟
GT Designer3 (GOT2000) Screen Design Manual (SH-081220ENG)
(d) Setting procedure from connecting an RFID controller to the GOT until reading IC tag data.
Refer to the following.
➟ GOT2000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) For GT
Works3 Version1 (SH-081200ENG)
(e) The send data and receive data for an RFID controller manufactured by MARS TOHKEN SOLUTION
CO.LTD.
1) ICU-60S
Send data: Set the data except STX and ETX to LF.
Receive data: The data except STX and ETX to LF are stored.
2) ICU-215
Send data: Set the data except STX and BCC to ETX.
Receive data: The data except STX and BCC to ETX are stored.
9.4 The following RFID controllers are available for the external authentication.
Manufacturer Model
LS Industrial Systems Co., Ltd. LSRF-C
OMRON Corporation V600/V620
PONGEE INDUSTRIES CO., LTD PUA-310