Specifications

[Issue No.] GOT-A-0064-C [Page] 33/39
[Title] List of Valid Devices Applicable for GOT2000 Series
[Date of Issue] Ver. C: February 2015 (First Edition: September 2013)
[Relevant Models] GOT2000 Series
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
TECHNICAL BULLETIN
9.3 How to read data by an RFID controller
Please refer to the followings for the data transfer format (header/terminator settings and others) that can be
used in the GOT or the setting method to read data by an RFID controller.
(a) Data transfer format (header/terminator settings and others) that can be used in the GOT.
(b) Setting to connect an RFID controller to the GOT. ([Peripheral Setting] on GT Designer3(GOT2000))
(c) Setting to write the data, read by an RFID controller, to the PLC CPU. ([Detail Setting] in the [Bar Code]
dialog box on GT Designer3(GOT2000))
Refer to the following.
GT Designer3 (GOT2000) Screen Design Manual (SH-081220ENG)
(d) Setting procedure from connecting an RFID controller to the GOT until reading IC tag data.
Refer to the following.
GOT2000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) For GT
Works3 Version1 (SH-081200ENG)
(e) The send data and receive data for an RFID controller manufactured by MARS TOHKEN SOLUTION
CO.LTD.
1) ICU-60S
Send data: Set the data except STX and ETX to LF.
Receive data: The data except STX and ETX to LF are stored.
2) ICU-215
Send data: Set the data except STX and BCC to ETX.
Receive data: The data except STX and BCC to ETX are stored.
9.4 The following RFID controllers are available for the external authentication.
Manufacturer Model
LS Industrial Systems Co., Ltd. LSRF-C
OMRON Corporation V600/V620
PONGEE INDUSTRIES CO., LTD PUA-310