(a) For the RS-485 connection
The following shows connection cables that must be produced by the user.
Maximum cable length: confirm with the RFID controller manufacturer.
RFID controller
Cable connection and signal direction
GOT
Signal name
Pin No.
Pin No.
Signal name
RDA(-) 1
1 SDA
RDB(+) 2 2 RDA
SDA(-) 3 3 RSA
SDB(+) 4 4 CSA
SG 5 5 SG
― ― 6 SDB
― ― 7 RDB
― ― 8 RSB
― ― 9 CSB
― ― ― FG
*For the cables between and , refer to the manual created by OMRON Corporation
(2) RS-422/485 cable (terminal block) connection diagram for an RFID controller (V600/V680)
manufactured by OMRON Corporation
The following shows connection cables that must be produced by the user.
Maximum cable length: confirm with the RFID controller manufacturer.
RFID controller
Cable connection and signal direction
GOT
Signal name
Pin No.
Pin No.
Signal name
RDA(-) 1
1 SDA1
RDB(+) 2 2 SDB1
SDA(-) 3 3 RDA1
SDB(+) 4 4 RDB1
SG 5 5 SDA2
― ― 6 SDB2
― ― 7 RDA2
― ― 8 RDB2
― ― 9 SG
― ― 10 FG