9.2.2 When using the RS-422/485 connection
The following shows the equipment to configure with different types of RFID controllers.
4
GOT
RS-422/485 cable
1
IC tag
2
RFID reader/writer
3
RFID controller
5
Option device of GOT
Manufacturer IC tag
RFID
reader/writer
RFID
controller
RS-232 cable
Option device
of GOT
OMRON Corporation
V600-D V600-H V600-CA5D
Produced by the user
Refer to (1) below
- (Built into GOT)
GT15-RS4-9S
Produced by the user
Refer to (2) below
GT15-RS4-TE
V680-D V680-H V680-CA5D
Produced by the user
Refer to (1) below
- (Built into GOT)
GT15-RS4-9S
Produced by the user
Refer to (2) below
GT15-RS4-TE
(1) RS-422/485 cable (D-sub, 9 pins) connection diagram for an RFID controller (V600/V680) manufactured
by OMRON Corporation
(a) For the RS-422 connection
The following shows connection cables that must be produced by the user.
Maximum cable length: confirm with the RFID controller manufacturer.
RFID controller
Cable connection and signal direction
GOT
Signal name
Pin No.
Pin No.
Signal name
RDA(-)
1
1 SDA
RDB(+) 2 2 RDA
SDA(-) 3 3 RSA
SDB(+) 4 4 CSA
SG 5 5 SG
6 SDB
7 RDB
8 RSB
9 CSB
FG