[Issue No.] GOT-A-0064-C [Page] 15/39
[Title] List of Valid Devices Applicable for GOT2000 Series
[Date of Issue] Ver. C: February 2015 (First Edition: September 2013)
[Relevant Models] GOT2000 Series
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
TECHNICAL BULLETIN
3.4 How to read data by a barcode reader
Please refer to the followings for the data transfer format (header/terminator settings and others) that can be
used in the GOT or the setting method to read data by a barcode reader.
(a) Data transfer format (header/terminator settings and others) that can be used in the GOT.
(b) Setting to connect a barcode reader to the GOT. ([Peripheral Setting] on GT Designer3(GOT2000))
(c) Setting to write the data, read by a barcode reader, to the PLC CPU. ([Detail Setting] in the [Bar Code]
dialog box on GT Designer3(GOT2000))
Refer to the following.
➟
GT Designer3 (GOT2000) Screen Design Manual (SH-081220ENG)
(d) Setting procedure from connecting a barcode reader to the GOT until reading a barcode.
Refer to the following.
➟
GOT2000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) For GT
Works3 Version1 (SH-081200ENG)
3.5 When using the GT21 model
To connect the barcode reader with the built-in RS-232 port (on the back side) of GT2103-PMBDS or
GT2103-PMBDS2, use the cable GT10-C02H-6PT9P.
To use GT2104-R, refer to the following and fabricate a cable for connecting the GOT.
■User cable
GOT side
(separate wire)
Ba
r
code
r
eade
r
side
(D-sub 9-pin)
2
3
6
4
5
7
8
RD
SD
DR
ER
SG
RS
CS
RXD
TXD
DSR
DTR
SG
RTS
CTS