Specifications
Chapter 2 Getting Started the BHT and System Mode
(1) Communications parameters setting screen
On the SET OPTICAL screen, select "1: PARAMETER" to call up the
screen shown at left.
Highlighted is the current setting.
Select the desired transmission speed by using the numerical keys o
r
F7 and F8 keys, and then press the ENT key.
To return to the SET OPTICAL screen, press the C key.
(2) Communications protocol option screen
On the SET OPTICAL screen, select "2: PROTOCOL" to call up the
screen shown at left.
Highlighted is the current setting.
[1] SERIAL No.: Selects whether or not to add serial numbers to
data blocks.
[2] H. PARITY: Selects whether or not to add a horizontal parity.
[3] LINKUP TIME: Selects the timeout length (in seconds) to be
applied when a link is to be established.
[4] FIELD SPACE: Specifies the treatment of trailing spaces in
fields.
To trim trailing spaces in fields, select Ignore; to
retain them as data, select Data.
Select a desired item by using the numerical keys or F5 and F6 keys.
Then select a desired setting by using the F7 and F8 keys.
To return to the SET OPTICAL screen, press the C key.
If the BHT-Ir protocol or YMODEM has been selected, the serial
number and horizontal parity settings will be ignored.
61