User`s manual
35
Chapter 7 Beeper, Indicator LED, Marker Beam, and Illumination LEDs
7.1 Beeper
(1) Beeping
The scanner emits a short or long beeps, once or a couple of times as described below.
The beeper emits a short beep when:
- the scanner has read a code successfully,
- code data read matches the master data in the data verification mode,(2-point:2 beeps, n-point:1 beep)
- the scanner has read a Structured Appended QR (iQR) Code symbol,
- the "Start setting" or "End setting" code is read (3 beeps) or the parameter setting QR Code symbols are read (1
beep) from the QR-coded parameter menu (given in Chapter 12),
- the configuration software (ScannerSetting_2D) starts up or accepts new settings (3 beeps), or
- the scanner has read a batch-process QR Code symbol generated with the configuration software
(ScannerSetting_2D) (3 beeps).
- a Bluetooth
®
wireless link is established, or
- the charge of the battery cartridge has lowered, turning the scanner off (5 beeps, slightly longer).
The beeper emits a long beep when:
- code data read does not match the master data in the data verification mode,
- the scanner has read Structured Appended QR (iQR) Code symbols in edit mode and the accumulated data exceeds 8
kilobytes,
- a master code has the wrong number of digits during registration of master data,
- a code other than a parameter setting code is read during parameter setting by the QR-coded parameter menu,
- a transmission error or timeout occurred when the scanner was communicating with the configuration software
(ScannerSetting_2D),
- the encryption key of data read does not match the one configured in the scanner in SQRC scanning (when the "data
transmission after mismatch of encryption key" is disabled),
- a communications error has occurred, or
- an invalid control command is received.
- a Bluetooth
®
wireless link is broken,
- transfer of communications adapter parameter settings is ended normally (1 beep) or abnormally (3 beeps), or
- the scanner has failed to save the parameter settings entered with the QR-coded parameter menu or the configuration
software.
When the scanner is turned on, the configuration software (ScannerSetting_2D) provides a choice of beeper ON/OFF
(default: ON), but does not provide a choice of beeper tone.
You can disable the beeper using the QR-coded parameter menu or configuration software (ScannerSetting_2D)*. In
any of the following cases, however, the beeper sounds regardless of that beeper setting:
- when you make settings by scanning the QR-coded parameter menu,
- when the scanner receives a beeper-ON command from the host computer,
- when the configuration software (ScannerSetting_2D) starts up or any setting you have made is established,
- when the scanner reads a batch-process QR Code symbol, and
- when the parameter values are saved by a PW command (refer to Appendix 2).
- when the Bluetooth wireless link is established or broken,
- when the charge of the battery cartridge has lowered,
-when the scanner has failed to save the parameter settings, or
-when transfer of communications adapter parameter settings is normally ended.