User`s manual

16
6.1.3 Verification result output
(1) Report of match/mismatch status
You can select any of the following report types using the configuration software (ScannerSetting_2D). Selecting
"Disable transmission" reports nothing.
If there is a match: If there is a mismatch:
Disable transmission. Disable transmission.
Code data transmission. Code data transmission.
OK transmission. NG transmission.
(2) Beeper and indicator LED
You can check whether the verification result is a match or mismatch with the beeper and indicator LED.
When the beeper and indicator LED are enabled, they act as shown below in default setting.
Beeper
Beeping times Beeping tone
Indicator LED
If there is a match: Emits a short 2 beeps. Middle beeping tone Lights in blue. 2-point
If there is a mismatch: Emits a long beep. High beeping tone Flashes in red.
If there is a match: Emits a short 1 beep. Middle beeping tone Lights in blue. n-point
If there is a mismatch: Emits a long beep. Middle beeping tone Flashes in red.
Output of the master data registered
Scanning the “Output master data” code given below lets the scanner output the verification section of master data
entered in the Data verification read procedure, together with the code ID mark.
“Output master data” code