(6) Data transmission format common to all interfaces
Items Parameters Defaults Refer to:
Enable
Transmission of code ID mark
Disable √
Section 9.4
Before prefix
Code ID mark position
After prefix √
Section 9.4
Type 1 (DENSO1) √
Type 2 (DENSO2)
Type 3
Type 4
Code ID mark
User-defined
Section 9.4, (5)
Coupling √
Code ID mark output mode
Separating
Section 9.4, (5)
Enable, in 4 digits
Enable, in 2 digits
Transmission of the number of digits
(not applicable to UPC/EAN codes)
Disable √
Section 9.4
Enable
Prefix transmission
Disable √
Enable
Suffix transmission
Disable √
Section 9.4, (3)
Enable
Scanner ID output
Disable √
Section 9.4, (2)
Enable
GTIN format conversion
Disable √
Conversion to 16 digits √
Conversion to 14 digits
Conversion type from UPC/EAN/
Interleaved 2of5 (14-digit) to GTIN format
Conversion prohibited
Conversion to 14 digits √
Conversion to 13 digits
Conversion type from RSS (GS1
DataBar)/EAN-128 (GS1-128) in GTIN
format to EAN format
Conversion prohibited
Prefix PI in conversion from UPC/EAN/
Interleaved 2of5 (14-digit) to GTIN format
0 to 9 0
Section 9.5
: Can be changed only with the configuration software.