User`s manual

26
Example Code read: QR Code, Data: (See the table below.)
Header: STX, Terminator: ETX, Scanner ID: Disable, Code ID mark: Disable,
Transmission of the number of digits: Disable, Prefix/Suffix: None, BCC: Disable
Extraction conditions Data read Data block numbers Output data
1,23,456,7890 1, 2 and 3 [STX]1[ETX][STX]23[ETX][STX]456[ETX]
1,23,456,7890 3, 1 and 2 [STX]456[ETX][STX]1[ETX][STX]23[ETX]
1234567890 1 [STX]1234567890[ETX]
1,,23,456,7890 2 and 5 [STX][ETX][STX]7890[ETX]
1,23,456,7890 5 Error
1,23,456,7890 4 and 5 Error
"Code type": QR Code
"Data transfer
regardless of error
result": Prohibit
1234567890 1 and 2 Error
1,23,456,7890 5 [STX]1,23,456,7890[ETX]
1,23,456,7890 4 and 5 [STX]1,23,456,7890[ETX]
"Code type": QR Code
"Data transfer
regardless of error
result": Permit
1234567890 1 and 2 [STX]1234567890[ETX]
"Code type": PDF417
"Data transfer
regardless of error
result": Prohibit
1,23,456,7890 Invalid if specified. Error
"Code type": PDF417
"Data transfer
regardless of error
result": Permit
1,23,456,7890 Invalid if specified. [STX]1,23,456,7890[ETX]