Specifications
[Issue No.] GOT-A-0010-S [Page] 20/28
[Title] List of Valid Devices Applicable for GOT1000 Series
[Date of Issue] Ver.S: December 2010 (First Edition: September 2005)
[Relevant Models] GOT1000 Series
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
TECHNICAL BULLETIN
(b) Cable connection diagram for an RFID controller manufactured by
MARS TECHNO SCIENCE Corp.
(ICU-60S)
RFID controller (ICU-60S) GOT
Signal name Pin No.
Cable connection and signal direction
Pin No. Signal name
+24V 1 1 CD *1
GND 2 2 RD(RXD)
TXD 3 3 SD(TXD)
RXD 4 4 DTR(ER)
CTS 5 5 SG
RTS 6 6 DSR(DR)
/RST 7 7 RS(RTS)
GND 8 8 CS(CTS)
-
9
9
-
*1: NC for GT11
*For the cables between
and , refer to the manual created by MARS TECHNO SCIENCE Corp.
(c) Cable connection diagram for an RFID controller manufactured by MARS TECHNO SCIENCE Corp.
(ICU-215)
RFID controller (ICU-215) GOT
Signal name Pin No.
Cable connection and signal direction
Pin No. Signal name
/RXD 1 1 CD *1
/TXD 2 2 RD(RXD)
+5V 3 3 SD(TXD)
GND 4 4 DTR(ER)
GND 5 5 SG
-
-
6 DSR(DR)
-
-
7 RS(RTS)
-
-
8 CS(CTS)
-
-
9 5V *2
*1: NC for GT11
*2: Supply 5VDC to the RFID controller.
*For the cables between
and , refer to the manual created by MARS TECHNO SCIENCE Corp.
(d) Cable connection diagram for an RFID controller (V600) manufactured by OMRON Corporation
RFID controller GOT
Signal name Pin No.
Cable connection and signal direction
Pin No. Signal name
-
1 1 CD
*1
SD 2 2 RD(RXD)
RD 3 3 SD(TXD)
RS 4 4 DTR(ER)
CS 5 5 SG
-
6 6 DSR(DR)
-
7 7 RS(RTS)
-
8 8 CS(CTS)
SG 9
9
-
*1: NC for GT11
*For the cables between
and , refer to the manual created by OMRON Corporation