Specifications
[Issue No.] GOT-A-0010-S [Page] 13/28
[Title] List of Valid Devices Applicable for GOT1000 Series
[Date of Issue] Ver.S: December 2010 (First Edition: September 2005)
[Relevant Models] GOT1000 Series
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
TECHNICAL BULLETIN
(d) Cable connection diagram for a 2D code reader manufactured by DENSO WAVE INCORPORATED
2D code reader GOT
Signal name Pin No.
Cable connection and signal direction
Pin No. Signal name
── ── ── ──
/TXD 2 2 RXD
/RXD
3
3 TXD
── ── ── ──
GND 5 5 SG
── ── ── ──
CTS 7 7 RTS
RTS 8 8 CTS
── ── ── ──
(3) Compatible 2D code type
Only “QR code” is supported by the GOT.
(4) How to read data by a 2D code reader
Please refer to the followings for the data transfer format (header/terminator settings and others) that can be
used in the GOT or the setting method to read data by a 2D code reader.
(a) Data transfer format (header/terminator settings and others) that can be used in the GOT.
(b) Setting to connect a 2D code reader to the GOT. ([Peripheral Setting] on GT Designer3 or [Communication
Settings] on GT Designer2)
(c) Setting to write the data, read by a 2D code reader, to the PLC CPU. ([Detail Setting] in the [Bar Code]
dialog box on GT Designer3 or [Detail Setting] in the [Bar Code] dialog box on GT Designer2)
Refer to the following.
- GT Designer3 Version□ Screen Design Manual (Fundamentals) (SH-080866ENG)
- GT Designer2 Version
□
Screen Design Manual (SH-080530ENG)
(d) Setting the procedure from connecting a 2D code reader to the GOT until reading 2D code data.
Refer to the following.
- GOT1000 Series Connection Manual (Microcomputer, MODBUS Products, Peripherals) for GT
Works3 (SH-080871ENG)
- GOT1000 Series Connection Manual (SH-080532ENG)