Specifications
Chapter 13. Barcode Reading
13.1. Outline
13.1.1. Enable Reading
BHT-700B
The BHT_EnableBar function enables the barcode device to read barcodes. In this function, you may
specify the following barcode types available in the BHT. The BHT can handle one of them or their
combination.
Available Barcode Type Default Setting
Universal product codes
EAN-13 (*1) (JAN-13 (*1))
EAN-8 (JAN-8)
UPC-A (*1), UPC-E
No national flag specified.
Interleaved 2of5 (ITF)
No length of read data specified.
No check digit.
Standard 2of5 (STF)
No length of read data specified.
No check digit.
Short format of the start/stop characters supported.
Codabar (NW-7)
No length of read data specified.
No check digit.
No start/stop character.
Code 39
No length of read data specified.
No check digit.
Code 93 No length of read data specified.
Code 128 (EAN-128) (*2) No length of read data specified.
Interleaved 2of5 (ITF)
No length of read data specified.
No check digit.
RSS Nothing specified.
(*1) Reading wide bars
EAN-13 and UPC-A barcodes may be wider than the readable area of the barcode reading window.
Such wider bars can be read by long-distance scanning. Pull the barcode reading window away from
the barcode so that the entire barcode comes into the illumination range.
(*2) Specifying Code 128 makes it possible to read not only Code 128 but also EAN-128.
38