User Guide
- 7 -
EVENT(or RESPONSE) and PARAMETER list (AMP)
EVENT PARAMETER
function example
PW ON POWER ON/STANDBY change PWON<CR>
STANDBY PWSTANDBY<CR>
MV ** MASTER VOLUME change, **:00 to 99 by ASCII MV80<CR>
98 = +18dB(MAX)
80 = 0dB
10 = -70dB
00 = -80dB
99 = ---(MIN)
CV FL ** CHANNEL VOLUME change, **:00 to 62 by ASCII CVFL **<CR>
CVFR 50<CR>
CVSW 50<CR>
FR ** 62 = +12dB(MAX), 38 = -12dB(MIN) CVFL 50<CR>
CVFR **<CR>
CVSW 50<CR>
SW ** 50 = 0dB CVFL 50<CR>
CVFR 50<CR>
CVSW **<CR>
MU ON OUTPUT MUTE ON/OFF change MUON<CR>
OFF MUOFF<CR>
SI DVD INPUT source change SIDVD<CR>
TUNER SITUNER<CR>
VCR-1 SIVCR-1<CR>
VCR-2 SIVCR-2<CR>
CDR/TAPE1 SICDR/TAPE1<CR>
NET/USB SINET/USB<CR>
IPOD SIIPOD<CR>
V.AUX SIV.AUX<CR>
SD
※1
AUTO DIGITAL INPUT mode change SDAUTO<CR>
PCM SDPCM<CR>
DTS SDDTS<CR>
ANALOG SDANALOG<CR>
MS
STEREO SURROUND mode change MSSTEREO<CR>