MIDI command input/output 
This unit supports USB MIDI output. Almost all MIDI control functions are supported. 
Setting the MIDI command transmission 
interval time
Depending on the computer specifications and OS type, the computer 
may not be able to receive the MIDI commands transmitted from this 
unit correctly. 
In this case, set the MIDI command transmission interval time to a 
larger value using the following operation. (The larger the value, the 
slower the control response.)
1
Press the power operation switch while 
simultaneously pressing PANEL, LIST, and X-F LINK.
The power switches on, the channel/master level meter lights, 
and the unit switches to the setting mode for MIDI command 
transmission interval time. 
2
Rotate the track select knob.
•For details on the relationship between the level display position 
of the channel/master level meter and the MIDI command 
transmission interval time, see “Setting value” and “Example”. 
•The factory setting is 4 msec. 
3
Press the track select knob.
The MIDI command transmission interval time is entered. 
4
Press SHIFT for DECK 1/3 or 2/4.
The settings are completed, and unit exits the setting mode. 
NOTE
It’s very unlikely that this setting needs to be changed from the default 
of 4 ms for newer computers. You should only change this to a higher 
setting in the case of communication issues with the DJ application.
MIDI control function
Input channels on deck control and mixer parts support the USB MIDI 
control function. The deck control part always issues MIDI commands 
based on panel operations. 
When the channel input source select knob of each input channel is 
set to PC, MIDI commands are output from each channel.
None of the sliding switches are compatible with MIDI output, with 
the exception of MIC1/2 LEVEL,  BOOTH ASSIGN and Cross fader 
assignment switch. 
 
 
 
 
  
 
 
   
 
 
 
チャンネル入力ソース
選択つまみ
チャンネル/マスター
レベルメーター
PANEL
トラック
選択つまみ
LIST
SHIFT
BOOTH ASSIGN
MIC1/2 LEVEL
電源スイッチ
SHIFT
X-F LINK
GSetting valueH
11 msec
12 msec
13 msec
14 msec
15 msec
16 msec
17 msec
18 msec
19 msec
20 msec
– msec
– msec
3 msec
4 msec
5 msec
6 msec
7 msec
8 msec
9 msec
10 msec
GExampleH
3 msec 4 msec (Default) 13 msec 20 msec
Channel input source 
select knob
Power operation switch
Track select 
knob
Channel/master 
level meter
Before use 
Connections 
Installing and setting up 
supplied software
Basic 
operations 
USB settings 
Other 
functions
Part names and 
functions 
Troubleshooting 
Specifications 
Index
System 
diagram 
Other 
functions