3.3 Servo Process Flow
Servo process
that has stopped
Starting flow
Initial setting
Tray control
Range of the
servo process
numbers
Processing items
Contents of each processNumber
00 00 Each initial setting
01 01 TRV initial movement
(Restrictions)
All processes that are under operation
cannot be displayed due to the limit of
the processing time.
Servo process
that is under
operation
1 2 0 9
START
TRV initial movement
02~08 02 Initial setting in FE system
05 Detecting LD ON HALF
08 Detecting CD LD ON
Disc detection
02~08 02 Initial setting in FE system
Disc type distinction
10~13 12 Focus ON
13 FBAL adjustment
Focus servo
14~15 15 Tracking ON
Tracking servo
17 17 Gain adjustment in ADSC
focus system
Gain learning
18~1A 19 DBAL/equalizer adjustment
1A ID read
ID read
Specification of the servo process