User Guide

15
SOFTWARE SPECIFICATIONS
1. Command List (ASCII Code is used to the commands)
Code Command Parameter Discription
Scan 1 byte, SCAN mode *(1) Performs the manual search (scan) with the selected direction and
speed.
A
B Back Cue Non Returns to the playback start position.
D End Moitor Non Starts the end monitor program.
Send Time 1 Byte, TIME mode *(1) Requests the time code with the frame unit.
E
F Eject Non Performs the disc eject operation.
H Send Reserved Track Non Requests the reserved track in the play mode, or programs step in the
program mode.
I Index Search 2 bytes (Track, Index) Searches the selected index.
Jump 1 byte, JUMP mode *(1) Jumps the track up or down with the selected type.
J
Frame Cueing 1 byte, Frames *(1) Moves the selected frames with block repeat form.
K
(1) b 7 b 6 b 5 b 4 b 3 b 2 b 1 b 0
X 0 0 0 0 0 0 0 : Block Repeat
X 0 0 0 0 0 0 1 : Step 1 Speed (About 2 Times)
X 0 0 0 0 0 1 0 : Step 2 Speed (About 4 Times)
X 0 0 0 0 1 0 0 : Step 3 Speed (About 8 Times)
X 0 0 0 1 0 0 0 : Step 4 Speed (About 12 Times)
X 0 0 1 0 0 0 0 : Step 5 Speed (About 16 Times)
X 0 0 1 1 0 0 0 : Step 6 Speed (About 24 Times)
X 0 1 0 0 0 0 0 : Step 7 Speed (About 32 Times)
0 X X X X X X X : Forward
1 X X X X X X X : Reverse
(1) b 7 b 6 b 5 b 4 b 3 b 2 b 1 b 0
0 0 0 0 0 0 0 0 : P-Time (Elapse)
0 0 0 0 0 0 0 1 : P-Time (Remain)
0 0 0 0 0 0 1 0 : A-Time (Elapse)
0 0 0 0 0 0 1 1 : A-Time (Remain)
(1) b 7 b 6 b 5 b 4 b 3 b 2 b 1 b 0
X X X X 0 0 0 1 : 1 Track Move
X X X X ~ : ~
X X X X 1 1 1 1 : 15 Tracks Move
X 1 X X X X X X : Track (fixed Code)
0 X X X X X X X : Forward
1 X X X X X X X : Reverse
(1) b 7 b 6 b 5 b 4 b 3 b 2 b 1 b 0
X 0 0 0 0 0 0 0 : No Move
X 0 0 0 0 0 0 1 : 1 Frame Move
X ~ : ~
X 1 1 1 1 1 1 1 : 127 Frame Move
0 X X X X X X X : Forward
1 X X X X X X X : Reverse