Operation Manual
51
Getting started
Part names
and functions
Connections Control functionSetting Defaults
File and folder
settings
Playback Information
parameter description
Number Numerical value
Name String Character string
TIME STRING Expression:MMM:SS;FF
Colon is used between MMM and SS (:) 0x3A
SemicolonisusedbetweenSSandFF(;)0x3B
MMM is displayed in 3 digits with 0 embedded expressions (000 - 999) In ASCII,
each digit is expressed in ASCII
SS is displayed in 2 digits with 0 embedded expressions (00 - 59) In ASCII, each
digit is expressed in ASCII
FF is displayed in 2 digits with 0 embedded expressions (00 - 74) In ASCII, each
digit is expressed in ASCII
012:34;56istransmittedas0x300x310x320x3A0x330x340x3b0x350x36
Dimmer Value 1 - 5 integer expression
Sample Rate Hzunitnumericalvalue
Lock No. 0:All Keys available
1:Only Transport Keys Available
2:All Keys Locked
Version No SSMMmmRR
SS is a specification code (0x00=A,0x01=B…0x19=Z)
MM is a major code(0 - 0x63)
MM is a minor code(0 - 0x63)
RR is a revision code (0 - 0x63)
Ex. When SSMMmmRR=0x00010000, A-1.00
File Name String
Folder Name String
Media Name String
Folder delimiter is ‘\(0x5C)’
Media name is “CDA:”, “CDD:”, “USB:”, or “NETxxx:”
CDA indicates CD-DA
CDD indicates CD-DATA
USB indicates USB storage
NETxxx indicates a server on the NET
Media name ends in ‘:’ (colon)
Folder name ends in ‘\’
<root> indicates “\\”
Absolute path is expressed as “\\Folder name\Folder name\”
Relative path is expressed as “Folder name\Folder name\”
Folder in one superior hierarchy level is expressed as “..\”
Current folder is expressed as “.\”
File name is expressed as “Track name:extension”
Combinations of the expressions above can be used
E.g.) Expression of a full path from the media “CDD:\\Folder name\Track name.
MP3”
E.g.) Expression of a full path from <root> “\\Folder name\Folder name\Track
name.MP3”
Serial remote control function
parameter description
Hot number Value from 1 - 20 1 byte, not ASCII coded even with ASCII systems
Track number Value from 0 - 1999 2 byte binary value. 0 - 7CF Transfer order from top down.
In ASCII systems, each digit of a track number expressed in base 10 is transferred
in ASCII code.
Range of 0x30 0x30 0x30 0x30 - 0x31 0x39 0x39 0x39.
Pitch value DN-700C has a range of ±16.00%. However, the second value after the decimal
is always 0.
This value is multiplied by 100 and transferred.
The specification range is ±999.99%.
In binary mode, a 3-byte value is transferred. Transfer order from top down.
In ASCII systems, each digit of a pitch expressed in base 10 is transferred in
ASCIIcode.Upperordervaluesarezerolled.
Transmission order is symbol, hundreds, tens, ones, first decimal, second
decimal.
The symbol is not coded to ASCII, and is sent as 0 or 1.
Current Track Audio
Format String
For PCM
WAV\Samplingrate\quantizationbitrate(WAVle)
AIF\Samplingrate\quantizationbitrate(AIFFle)
For compressed formats
MP3\Sampling rate\Bit rate (MP3 file)
M4A\Sampling rate\Bit rate (AAC/iTunes format)
MP4\Sampling rate\Bit rate (MP4 file)
AAC\Sampling rate\Bit rate (AAC/Winamp5 format)
Sampling rate: Hz unit numerical value. In the ASCII format, each digit is
converted to ASCII.
Quantizationbitnumber:bitnumbersuchas16/24etc.IntheASCIIformat,each
digit is converted to ASCII.
Bit Rate: Numerical value in kbps unit such as 320 etc. In the ASCII format, each
digit is converted to ASCII.
NOTE
About the command list see page “Appendix”.