Specifications
.21 Request Error status
This command acquires the Error status. When an error occurs, all units become the STOP mode.
bytebit 7 6 5 4 3 2 1 0
0 STX 02h
1 Command code 7
2 ETX 03h
3 BCCH high-level
4 BCCH low-level
Answers returned
bytebit 7 6 5 4 3 2 1 0
0 STX02h
1
Reply code ’7’
2 Answer code
3
Error-occurred player ID (‘0’ to ‘5’)
4 1st error code (1000 digits) (ASCII)
5 1st error code (100 digits) (ASCII)
6 1st error code (10 digits) (ASCII)
7 1st error code (1 digit) (ASCII)
8 2nd error code (100 digits) (ASCII)
9 2nd error code (10 digits) (ASCII)
10 2nd error code (1 digit) (ASCII)
11 ETX 03h
12 BCCH high-level
13 BCCH low-level
Special condition
· When no error occurs, bytes 3 to 10 becomes ‘0’.
Other
· For error codes, see item 3.
· After an error occurs, only the OPEN key on the DCM-5000/5001 is available. Do not open
and remove the CD rack by force. Follow the instructions in "Error Code List (3)."
· To restart the DCM-5000/5001 after removing the error cause, turn off power of all units, then
turn on power switches of the units in the preset power-on sequence.