User Guide

13
DCD-710AE
2.6
Laser current is
display
When the 2 button is pressed for over 1 second
while the DCD-710AE is in the stop mode, the
laser turns on and the laser current is measured.
The laser drive current undergoes A/D
conversion for calculation. Decimal values are
discarded.
The first current value is measured 3 seconds
after the laser turns on.
The current value is updated every 3 seconds.
Press the 2 button, CD test mode display (2)
reappears.
Stored data is not cleared, even when the DCD-
710AE is reset.
q Overwriting the stored data
When the
/
13 button is pressed for over 5
seconds while the laser current is displayed, the
current value is stored in the EEPROM
(overwriting the stored data).
Once rewriting is completed, the display in 2.6
reappears.
13 flashing
XX : Stored data : EEPROM Stored value
YY : Current value
q
2.7
Adjustment value
display
Press the 2 button after executing the servo auto
adjustment.
When 9 button is pressed, the adjustment
values are displayed in the following order.
q FOCUS BALANCE
w FOCUS GAIN
e TRACKING BALANCE
r TRACKING GAIN
tFOCUS OFFSET
y TRACKING OFFSET
13 flashing
q
XX : Adjustment value
w
XX : Adjustment value
e
XX : Adjustment value
r
XX : Adjustment value
t
XX : Adjustment value
y
XX : Adjustment value
No
Key name
Function Display
S
/C: XXmA/ YYmA
L
ASER CURRENT
S
TORED
L
ASER CURRENT
X
X
F
OCUS BALANCE
X
X
F
OCUS GAIN
X
X
T
RACKING BALANCE
X
X
T
RACKING GAIN
X
X
F
OCUS OFFSET
X
X
T
RACKING OFFSET