Protocol Specs
- 33 -
EVENT PARAMETER
function example
Z2 PHONO ZONE2 source change Z2PHONO<CR>
| ---The name of PARAMETER is |
USB DIRECT
IPOD DIRECT
the same as that of the time of SI COMMAND. Z2USB DIRECT<CR>
Z2IPOD DIRECT<CR>
SOURCE ZONE2 mode cancel Z2SOURCE<CR>
QUICK1 ZONE2 QUICK SELECT mode change Z2QUICK1<CR>
QUICK2 Z2QUICK2<CR>
QUICK3 Z2QUICK3<CR>
QUICK4 Z2QUICK4<CR>
QUICK5 Z2QUICK5<CR>
QUICK0 ---Z2 QUICK SELECT 1(or 2, 3, 4, 5)
Change QUICK SELCT OFF
Z2QUICK0<CR>
** ZONE2 VOLUME change , **:00 to 99 by ASCII Z280<CR>
98 = 18dB(MAX)
80 = 0dB
10 = -70dB
00 = -80dB
99 = ---(MIN)
ON ZONE2 ON/OFF change Z2ON<CR>
OFF Z2OFF<CR>
Z2MU ON ZONE2 OUTPUT MUTE ON/OFF change Z2MUON<CR>
OFF Z2MUOFF<CR>
Z2CS ST ZONE2 Channel setting Z2CSST<CR>
MONO Z2CSMONO<CR>
Z2CV FL ** **:38 to 62 by ASCII , 50=0dB Z2CVFL 50<CR>
FR ** **:38 to 62 by ASCII , 50=0dB Z2CVFR 50<CR>
Z2HPF ON ZONE2 HPF ON/OFF change Z2HPFON<CR>
OFF Z2HPFOFF<CR>
Z2PS BAS ** ZONE2 BASS change
Z2PSBAS 50<CR>
TRE ** ZONE2 TEBLE change
Z2PSTRE 50<CR>
The PARAMETER of Z2 EVENT : Uses two ASCII characters. (see page4 J) section)