Protocol Specs

- 11 -
COMMAND PARAMETER
function example
PS MULTEQ:AUDYSSEY MultEQ mode direct change PSMULTEQ:AUDYSSEY<CR>
MULTEQ:BYP.LR PSMULTEQ:BYP.LR<CR>
MULTEQ:FLAT PSMULTEQ:FLAT<CR>
MULTEQ:MANUAL PSMULTEQ:MANUAL<CR>
MULTEQ:OFF PSMULTEQ:OFF<CR>
MULTEQ: ? Return PSMULTEQ: Status PSMULTEQ: ?<CR>
DYNEQ ON Dynamic EQ = ON PSDYNEQ ON<CR>
DYNEQ OFF Dynamic EQ = OFF PSDYNEQ OFF<CR>
DYNEQ ? Return PSDYNEQ Status PSDYNEQ ?<CR>
REFLEV 0 Reference Level Offset=0dB PSREFLEV 0<CR>
REFLEV 5 Reference Level Offset=5dB PSREFLEV 5<CR>
REFLEV 10 Reference Level Offset=10dB PSREFLEV 10<CR>
REFLEV 15 Reference Level Offset=15dB PSREFLEV 15<CR>
REFREV ? Return PSREFLEV Status PSREFLEV ?<CR>
DYNVOL NGT
Dynamic Volume = Midnight
PSDYNVOL NGT<CR>
DYNVOL EVE
Dynamic Volume = Evening
PSDYNVOL EVE<CR>
DYNVOL DAY
Dynamic Volume = Day
PSDYNVOL DAY<CR>
DYNVOL ?
Return PSDYNVOL Status
PSDYNVOL ?<CR>
PS COMMAND : "*" parameter uses two ASCII characters. (see page6 J) section)