Instruction Manual
I-1384 Page 9 of 16
Rev. -- 47069 8/23/2021
Default Formula
This feature allows the system to be setup so that when the load count pump is operated on
any given formula the system will then change to the default formula setting.
1. Use the UP and DOWN button to scroll through the Programming Menu to find Default
Formula and press ENTER. The display then should show either “NO DEFUALT
FORM” or FORMULA = x.
2. This can be changed by pressing ENTER and adjust to the desired setting of “no default
formula” or a default formula.
3. Press ENTER to accept the new setting.
Assign Triggers (only displayed in Formula Select Mode)
This feature allows any pump to be assigned to any trigger signal input.
1. Use the UP and DOWN to scroll through the Programming Menu to find Assign
Triggers. Press ENTER and the Assign Triggers screen will be displayed.
2. Use the UP and DOWN to move the asterisk (*) to the desired pump. Press ENTER and
cursor will flash.
3. Use the UP and DOWN to change the desired trigger signal input number.
4. Press ENTER to save the new setting.
5. Repeat steps 2 – 4 for any additional pumps.
6. Press LEFT to move back to the main Program Menu.
Enter Sequence –Drain Mode (only displayed in Sequence mode)
1. Use the UP and DOWN scroll through the Programming Menu to find Enter Sequence
and press ENTER. The Sequence screen will be displayed.
2. Use the UP and DOWN to move the asterisk (*) on the right side next to the Formula
number. Press the ENTER to change the formula. A cursor will flash next to the
formula number.
3. Use the UP and DOWN to change to the desired formula number. When the desired
formula number is displayed, press the ENTER button.
4. Use the DOWN to move the asterisk (*) from Formula to Sequence. Press the ENTER
to change the sequence number. A cursor will flash next to the sequence number.
a. Use the UP and DOWN to change to the desired sequence number. When the
desired sequence number is displayed, press the ENTER.
b. Use the DOWN to move the asterisk (*) to the row of pump numbers along the
bottom edge of display.
c. Press the ENTER to program pumps to run at the displayed Sequence number.
d. A cursor will flash over the number 1 in the pump row. Use the RIGHT and
LEFT buttons to move the cursor and the UP and DOWN to add to run a pump
or remove a pump operation that had been previously programmed. When UP
is pressed an asterisk (*) will appear indicating that this pump will run. When
DOWN is pressed the asterisk (*) will be removed, indicating that the pump will
not run.
Note: The “F” in the pump row represents the final sequence event (for example, the
final fill on a laundry machine). Program an asterisk (*) above the “F” when used
as the final sequence event. This will reset the sequence count for a new wash
cycle. Pumps can be programmed to run on the final event.
5. Repeat step 4 for all sequence events in the displayed formula.
6. Repeat all steps for additional formulas.
Note: Each formula will require complete sequence mode programming.
Configuration
Formula Lockout
Program Formula
Enter Sequence
Formula 1
Sequence = 01
* - - - - -
1 2 3 4 5 F
Program Formula
Default Formula
Assign Triggers
Load Count Pump
Program Formula
Default Formula
Assign Triggers
Load Count Pump
Assign Triggers
P1 1 P4 4
*P2 2 P5 5
P3 3