Instruction Manual

I-1384 Page 8 of 16
Rev. -- 47069 8/23/2021
Note: This is the post flush time. The flush will automatically run with the pump if the flush
time is set to 1 or more seconds.
8. Press the ENTER button to save the flush setting.
9. Press LEFT button to return to Programming Menu.
Notes:
If 6 pumps are configured, the flush option is not available & the number 6 pump will
need to be operated triggers 1-5, as there is no number 6 trigger input available.
Flush time has a range of 1-999 seconds.
When the six pump option is selected in Formula Select or Relay modes one of the first
five triggers must be selected to operate pump six.
Formula Lockout
This feature allows the system to only operate pumps once from a given trigger signal input.
Any subsequent trigger signals will be ignored during the active Formula Lockout clock.
The Formula Lockout clock starts on the first trigger signal received to any of the 5 trigger
signal inputs. At that point the active Formula Lockout clock will apply to all trigger signal
inputs.
1. Use the UP and Down to scroll through the Programming Menu until you find the menu
Formula Lockout and press ENTER.
2. Use the UP and DOWN to select the formula.
3. Press the ENTER to change the lockout time for the selected formula.
4. Use the UP and DOWN to set the lockout time for the length of the wash cycle for each
formula. The time measurement is in minutes.
5. Press the ENTER key to save setting.
6. Press the LEFT arrow button to return to the Programming Menu.
Program Formula (9 Formulas Max, will not display in Relay mode)
This will program pump run times for Level 1, Level 2, and Delay times for each pump.
1. Use the UP and DOWN to scroll through the Programming Menu and find Program
Formula and press ENTER. An asterisk (*) will appear as a cursor.
2. With the asterisk next to the “Form” number. Press ENTER to change the formula to be
programmed.
3. When desired formula number is displayed, press ENTER to program pumps.
a. Use the LEFT and RIGHT to move from Level 1, Level 2 and Delay
programming.
b. Use the UP and DOWN to select a pump or move back to the FORM selection.
c. Press the ENTER when at the desired pump to program a pump run time or
delay.
d. Use the UP and DOWN to adjust the pump run or delay time. The range is 0-
999. The units are as follows:
i. Seconds for Formula Select and Sequence Modes
ii. Minutes for Push Button Mode
e. Press ENTER to save the setting.
f. Repeat step 3 process for all pump runs and delay times.
4. Repeat steps 2 & 3 to program additional formulas.
5. Press the LEFT to return Program Formula screen.
Note: Only the number of pumps that were set in the configuration setup will be displayed
in the program formula screens. Also, all pump run times are in seconds.
Configuration
Pumps 5
Flush 001s
Formula Lockout
Formula 1
Time in Min = 00
Operation Mode
Configuration
Formula Lockout
Program Formula
Form 1 Level 1
P1 020s P4 020s
P2 020s P5 020s
P3 020s
Operation Mode
Configuration
Formula Lockout
Program Formula
Form 1 Level 2
P1 020s P4 020s
P2 020s P5 020s
P3 020s
Form 1 Delay
P1 020s P4 020s
P2 020s P5 020s
P3 020s