Instruction Manual
I-1384 Page 12 of 16
Rev. -- 47069 8/23/2021
Exit Programming
Press the ENTER key to return to the Formula screens. Pressing the LEFT arrow from any
of the menu screens will display this screen.
User Functions and Operation
Changing Formulas at the User Screen
When powered and sitting idle, the Dairy Clean will display the formula, the formula load
count and the total load counts for all formulas. Changing Formulas at the Front of the Dairy
Clean;
There are three ways to select a formula in all operating modes:
1. The formula may be selected using the UP and DOWN arrows on the dispenser.
2. The Dairy Clean Formula Selector remote may be used to select a formula.
3. Auto Formula Select - see the Auto Formula Select in the Trigger Wiring Section.
Run a Formula
A formula will be started according to Operating Mode that was set through the
programming screens.
• For Push Button mode press the ENTER on the front of Dairy Clean or the START
on the Formula Selector Remote and all pumps will start with their delay time
followed by their run time.
• For Formula Select mode each pump will respond to its individual trigger.
• For Sequence mode each pump will operate at the input sequence that was
programmed.
• For Relay mode each pump will respond to its respective trigger.
When a formula is running the load count will be replaced with a status indicator for each
pump. The indicator will show the pump number. The pump number will be above a “D”
for delay, an “R” for run, a “-“ for finished, an “H” for hold, or an “L” for locked out. A “-“
indicates that the pump has not yet been triggered. When a flush is used a “+” indicates the
flush is running. When the lockout time has expired the display will return to the load
counts for the formula.
Prime Pump
1. From the formula select screen press and hold the Left arrow for at least 10 seconds. The
Prime Pump screen will be displayed.
2. Use the UP and DOWN to select the desired pump.
3. Press ENTER to start priming.
4. Press ENTER again to stop the pump.
5. To exit the Prime Pump screen, hit the RIGHT arrow and that will take you back to the
Formula select screen
Note : If the pump is left running it will automatically stop after 2 minutes.
Test Formulas
Enter New Code
Set Defaults
Exit Program
Exit Programming
Press Enter
Formula 1
Load 0000
Total Loads 0000
Prime Pump 1
Enter to Start
Prime Pump 1