Instruction Manual

I-1384 Page 11 of 16
Rev. -- 47069 8/23/2021
Set Defaults (and Copy Program)
CAUTION Using this feature will erase all programming and restore the dispenser to
factory settings.
1. Using the UP and DOWN scroll through the Program Menu and find Set Defaults.
Press Enter and the Set Factory Default screen will be displayed.
2. Press ENTER to clear and restore the system to the factory defaults. A screen will
appear that has a flashing cursor next to the word “no”.
3. Use the UP or DOWN change to “yes” or back to “no”.
a. Press ENTER with “yes” displayed to clear the programs and restore the factory
defaults. The display will show the system restoring and eventually display
“memory cleared”.
b. Press ENTER with “no” displayed to move back to previous screen without
clearing and restoring factory defaults.
4. Press the LEFT to return to the Program Menu.
Copy a program (use Set Defaults)
Using the Copy Cable (DEMA P/N 84.254.1) programming from another Dairy Clean can
be imported to the Dairy Clean.
1. Turn main power off to each Dairy Clean using the power switch at the bottom of the
Dairy Clean control module.
2. Turn power off to all contollers or equipment that the trigger cable of each Dairy Clean
may be connected.
Caution - Before going any further assure that no power is being supplied to the
trigger cables to each Dairy Clean.
3. Remove the 4 screws from the front face of both Dairy Cleans and loosen the front face
to access the control board.
4. Using the Copy Cable, connect the cable to the Data Port on each Dairy Clean control
board.
5. Turn the main power to each Dairy Clean on using the main power switch at the bottom
of the Dairy Clean control module.
6. Enter programming on the Dairy Clean that will receive the programming (not the Dairy
Clean that has been programmed).
7. Use the UP and DOWN to scroll through the Program Menu and find Set Defaults.
Press ENTER and the Set Factory Defaults screen will be displayed.
8. Press ENTER to clear any programming and import new programming. A screen will
appear that has a flashing cursor next to the word “no”.
9. Use the UP or DOWN and change to “yes”.
10. Press ENTER and the display will show the system restoring and eventually display
“memory cleared, import program, no”.
11. Press ENTER and a cursor will flash next to the word “no”.
12. Use the UP or DOWN to change to “yes”.
13. Press ENTER and “copying” will be displayed. Eventually this will change to
“finished”. At this point the program has successfully been copied to the Dairy Clean.
14. Turn the main power off to the Dairy Cleans.
15. Remove the data cable and reassemble the front face to the Dairy Cleans using the (4)
screws.
Trigger Time
Test Formula
Enter New Code
Set Defaults
Set Factory
Default
Press Enter
Memory Cleared
Import Program
Yes
Memory Cleared
Import Program
Copying
Memory Cleared
Import Program
Finished
Set Factory
Default
Press Enter
Set Factory
Default - Yes
Trigger Time
Test Formula
Enter New Code
Set Defaults