Instruction Manual

I-1384 Page 10 of 16
Rev. -- 47069 8/23/2021
Load Count Pump (not displayed in Relay mode)
Select a pump for each formula that will be counted each time it is operated (does not count
when pump is primed).
1. Scroll through the Programming Menu to find Load Count Pump and press ENTER.
2. Use the UP and DOWN to select the formula. Press ENTER to change the displayed
load count pump for the displayed formula. A cursor will flash next to the setting.
3. Use UP and DOWN to select a desired load count pump.
4. Press the ENTER to save the results.
5. Press LEFT to return to the Program Menu.
Trigger Time (only displayed in Formula Select, Flex Trigger or Sequence modes)
Programs a qaulification time for triggers received. The trigger time defines how long an
uninterupted trigger signal from the controller is required to start a pump operation. The
range is 2 to 90 seconds. The factory default is 5 seconds.
1. Use the UP and DOWN to scroll through the Programming Menu to find Trigger Time
and press ENTER. The Trigger Time program menu will be displayed.
2. Press ENTER to modify the trigger time. A cursor will flash next to the trigger time.
3. Use the UP and DOWN to adjust the time.
4. Press the ENTER key to save the displayed trigger time.
5. Press LEFT to return to the Program Menu.
Test Formulas
Tests the output of the programmed pump by allowing a button to activate the operation in
any formula and pump run time. See procedure below:
1. Scroll through the Programming Menu to find Test Formulas and press ENTER.
2. To Select the Formula:
a. Use UP and DOWN to move the asterisk to the Formula Setting and press
ENTER. A cursor will flash next to the formula number.
b. Use UP and DOWN to find the desired formula and press ENTER when the
desired formula number is displayed.
3. To Select the pump to be tested;
a. Use UP and DOWN to move the asterisk (*) to the Pump Setting and press
ENTER. A cursor will begin to flash on the far right of the Pump Setting.
b. Use UP and DOWN button to select a Pump and RT (Level 1 or Level 2 run
time). When the desired Pump and RT are displayed press ENTER.
4. To Test the Pump Output or Time;
a. Use UP and DOWN to move the asterisk to the Start selection.
b. Press ENTER to start the pump and allow the pump to operate an either time or
collect the output in a graduated cylinder to check for accuracy.
Note: When the pump is running the “Start” function will become a “Stop” function.
The pump can be stopped if necessary.
Enter Code
Allows a unique passcode to be setup for accessing programming. Passcode is 4 numeric
characters.
1. Using the UP and DOWN scroll through the Program Menu and find Enter New Code.
Press ENTER and the Enter New Code screen will be displayed.
2. Press ENTER to modify the access code. 4 zeros and a flashing cursor will be displayed.
3. Use the LEFT and RIGHT and UP and DOWN to change the 4 zeros to the desired
access code.
4. Press ENTER when the desired access code is displayed. The change will be complete.
5. Press the LEFT to return to the Program Menu.
Note: If you forget the password, call DEMA Technical Service for directions on how to
reset the password.
Formula Lockout
Program Formula
Enter Sequence
Load Count Pump
Load Count
Formula 1
Pump = 1
Program Formula
Enter Sequence
Load Count Pump
Trigger Time
Trigger Time
05s 2-90s
Press Enter
Enter Sequence
Load Count Pump
Trigger Time
Test Formulas
Enter Code
Press Enter
Load Count Pump
Trigger Time
Test Formula
Enter New Code
Test Formula
Formula 1
Pump = 1 RT 1
Start