Troubleshooting guide
The M2 is a free standing, floor mounted, wire stitcher. The following parts must be assembled
after shipment: work table, spool bracket, spool stud, wire spool, adjuster handwheel handle, and wire
guide springs. The M2 can be lagged to the floor, if desired, after leveling.
Thread the wire onto the head and make adjustments to wire length & straightness as described in
the head Operation Manual.
Electrical power is provided through the attached line cord to be connected to an appropriate supply
outlet rated as shown:
6
The plastic belt guard must first be removed before the M2 can be turned over manually. To remove
the belt guard, remove the retaining screw from the top of guard. Press on one side tab while prying
out the locking face. This will release the first tab. Next, pull down slightly on the top of the guard
to release the bottom tab. Guard will now be free to lift off remaining tabs on mounting plate.
To reassemble, interlock the top tab and one side tab. Pull down slightly on top of guard to interlock
bottom tab, then squeeze mounting plate and guard together to lock remaining tab, completing
assembly. Reassemble the retaining screw at the top of the guard.
To turn the machine manually, it is necessary to first disconnect the power and remove the belt guard
Belt Guard Removal and Assembly
Always disconnect the power supply before making any
adjustments or servicing the stitcher.
WARNING
!
Installation
Do not operate the M2 under power until the machine
has been turned over manually (see below) to verify that
the stitching heads are operating freely.
WARNING
!
SUPPLY POWER 115V / 60HZ 230V / 50HZ
M2 Rated Current 9.2A 4.6A
M2 Interrupt Current, 12kA 12kA
Internal Breaker