Specifications

26
problem: Partially Formed Stitches
solution: Replace the worn Driver Bar Latch (9014) or Driver
Bar (9012A). The Grip Spring (9019) could be worn or broken, replace it.
problem: Stitch in Pieces or Right or Left Leg Sheared Off
solution: Clean and lubricate Swivel (9038A or 9038M). (See page 19)
Loosen the Swivel Holder Screw and correct the alignment between the
Swivel Holder and the Bender Bar. If problem persists, file the forming
corner of the Swivel slightly with a honing stone.
problem: Left Leg Missing
solution: Clean the Grip (9015). Reverse or replace the part if
needed. (See page 22) Make sure the Wire Straightener Rollers are not set
too tight. Make sure the Tension Pawl is not worn and is pivoting correctly.
(See page 21)
problem: Corner of stitch broken or nearly cut through
solution: File the forming corner of the Swivel slightly with a honing
stone if too sharp. Lower Clincher Points (9083) if too high. (See page 16)
Loosen the Swivel Holder Screw and correct the alignment between the
Swivel Holder and the Bender Bar.
problem: Corners of the Crown are Rounded
solution: Replace the worn Swivel (9038A or 9038M).
problem: Loose Clinch
solution: Check thickness setting for work or raise Clincher Points
(9083). (See page 17)
problem: Legs are Spread or Contracted
solution: Re-adjust the Wire Straightener Eccentrics to improve
straightness. (See page 13) Check the Wire Cutters for wear and
rotate or replace. (See page 20) Check the Bender Bar (9013BA-wire size)
for wear in the grooves and replace if necessary.
problem: No wire being drawn
solution: Lower the Face Plate. (See page 15)
Figure 20 - Troubleshooting