Specifications
The following instructions illustrate how to
calibrate the G8 Stitcher Head the first time it is used
after mounting it to the stitcher machine. It also
illustrates how to manually adjust the Cutter Block
each time a different stitching capacity is required.
Adjust the compression setting on the stitcher
machine for the capacity of work to be stitched.
Make a few sample stitches and turn the stock away
from you to look at the results.
The length of each staple leg should equal the other,
meaning, the amount of wire on either side of the
stitch gap should be the same. The gap position is
controlled by the position of the Cutter Block
Assembly (G20197AA). As thicker work is stitched,
the Cutter Block must be moved further from the
Wire Holder Assembly in order to keep the legs of
the stitch even and the gap centered.
For G8 Heads mounted to a machine with an
adjuster rail, first loosen the two (2) Hex Head
Screws (G20289) securing the Lower Cutter Block Adjustment Bar and Cutter Block Adjustment
Connector (G20246) to the Upper Cutter Block Adjustment Bar (G20245 or G20251). For all G8
style Heads, place the Adjustment Knob (G20228A) over the Cutter Adjustment Stud (G20237) and
engage the teeth of the Cutter Block Adjustment Rack (G20143). To shorten the length of the left
staple leg, lengthen the length of the right staple leg or move the gap between the legs to the left: turn
the Adjustment Knob counter-clockwise. Run a couple of stitches to test this setting. To lengthen the
length of the left staple leg, shorten the length of the right staple leg or move the gap between the legs
to the right: turn the Adjustment Knob clockwise. If both legs are equal in length or if the gap between
the legs is centered, no more adjustment is necessary. Make sure to tighten the two (2) Hex Head
Screws securing the Lower Cutter Block Adjustment Bar and the Cutter Block Adjustment Connector
to the Upper Cutter Block Adjustment Bar.
If more adjustment is necessary, continue to move the Cutter Block Assembly towards or away from
the body of the G8 Stitcher using the Adjustment Knob and test after each adjustment.
16
Adjusting the Length of the Stitch Leg (Figure 9)
Figure 9 - Adjusting the Stitch Leg
G20197AA
G20228A
G20245
G20251
G20289 (2)
G20246
G20237
G20143