User Manual
Table Of Contents
FiberDistributedAntennaSystem(FiberDAS)
37
TheBlocknumbersandthenumbersinthecirclesref ertothenumbersonthepreviousconnectiondrawing.The
firstframe(BLOCK1)holdsalltheBIUinterfaces.Forclaritytheinterconnectingcablesarenotshownhere.The
secondshelf(BLOCK2)isthe2POIunitsandthehybridcombiner
(2:3and2:4)ishiddeninsidethecabinet.
Thethirdframe(BLOCK3)holdstheFOIcards,upto16cardscanbeheldinonesuchframe.ThenthereistheBGW
computer(BLOCK4)tyingallthecommunicationtogetherandprovidingthewebinterfaceforsettingupand
controllingthesystem.TheBGWalsohasanoptional
“northbound”fire‐walledconnectionthatcanbeconnectedto
yourownnetworkforremotesupervision,alarmandcontrol.ItcanevenbetunneledovertheInternetproviding
thereisaCGWunitwherethetunnelterminates.
BeneaththeBGWisaframecontainingaretwoPSU’s(BLOCK5).Theycanbeupgradedtofourunitstoprovide
redundancyforthisexample,twodifferentPSU’scanfeedthesameframe.
TheEthernetSwitch(BLOCK6)islocatedatthebottom,thisiswhereyouconnectalaptoptosetupandcommission
thesystem.