Technical data
Table Of Contents

June 2005
38
For more information visit: www.EatonElectrical.ca CAT.02.02.S.K.CD
XT IEC Power Control
Contactors, Starters and Overload Relays
Product Selection
Reversing Starters
Table 56. Full Voltage Reversing Starters with Screw Terminals
Underscore (_) indicates magnet coil suffix required. See Table 57.
Underscore (_) indicates overload relay suffix required. See Table 58.
Available August 2005.
Table 57. Magnet Coil Suffix
For indicated coils, price adder of 10% must be applied to the contactor list price in Table 56.
With DC Operation: Integrated diode-resistor combination, coil rating 2.6W.
Available October 2005, Frame C – D only.
Note:
IEC Utilization Categories, see Page 178,
Reference Data.
AC-1: Non-inductive or slightly inductive
loads.
AC-3: Squirrel-cage motors — starting
switching of motors during running.
AC-4: Squirrel-cage motors — starting,
plugging, inching.
I
e
(A) Maximum kW Ratings AC-3 Maximum 3-Phase Motor Rating Catalog
Number
Price
AC-3 3-Phase Motors 50 – 60 Hz 1-Phase hp Ratings 3-Phase hp Ratings AC Coil DC Coil
220/
230V
380/
400V
415V 660/
690V
115V 230V 200V 230V 460V 575V
Frame B
7
9
12
2.2
2.5
3.5
3
4
5.5
4
5.5
7
3.5
4.5
6.5
1/4
1/2
1
1
1-1/2
2
1-1/2
3
3
2
3
3
3
5
10
5
7-1/2
10
XTAR007B21_ _
XTAR009B21_ _
XTAR012B21_ _
Frame C
18
25
32
5
7.5
10
7.5
11
15
8
14.5
18
11
14
17
2
2
3
3
5
5
5
7-1/2
10
5
7-1/2
10
10
15
20
15
20
25
XTAR018C21_ _
XTAR025C21_ _
XTAR032C21_ _
Frame D
40
50
65
12.5
15.5
20
18.5
22
30
24
30
39
23
30
35
3
3
5
7-1/2
10
15
10
15
20
15
20
25
30
40
50
40
50
60
XTAR040D11_ _
XTAR050D11_ _
XTAR065D11_ _
Frame F
80
95
25
30
37
45
48
57
63
75
7-1/2
7-1/2
15
15
25
25
30
40
60
75
75
100
XTAR080F11_ _
XTAR095F11_ _
Frame G
115
150
37
48
55
75
70
91
105
125
10
15
25
30
40
40
50
60
100
125
125
150
XTAR115G11_ _
XTAR150G11_ _
Coil Voltage Suffix Code
Frame A – B
110V 50 Hz, 120V 60 Hz A
220V 50 Hz, 240V 60 Hz B
230V 50 Hz F
24V 50/60 Hz T
24V DC TD
415V 50 Hz, 480V 60 Hz C
550V 50 Hz, 600V 60 Hz D
208V 60 Hz E
190V 50 Hz, 220V 60 Hz G
240V 50 Hz, 277V 60 Hz H
380V 50 Hz, 440V 60 Hz L
400V 50 Hz N
380V 60 Hz P
12V 50/60 Hz R
24V 50 Hz U
42V 50 Hz, 48V 60 Hz W
48V 50 Hz Y
120V DC AD
220V DC BD
12V DC RD
48V DC WD
Coil Voltage Suffix Code
Frame C – F
110V 50 Hz, 120V 60 Hz A
220V 50 Hz, 240V 60 Hz B
230V 50 Hz F
24V 50/60 Hz T
24 – 27V DC TD
415V 50 Hz, 480V 60 Hz C
550V 50 Hz, 600V 60 Hz D
208V 60 Hz E
190V 50 Hz, 220V 60 Hz G
240V 50 Hz, 277V 60 Hz H
380V 50 Hz, 440V 60 Hz L
400V 50 Hz N
380V 60 Hz P
12V 50/60 Hz R
24V 50 Hz U
42V 50 Hz, 48V 60 Hz W
48V 50 Hz Y
110 – 130V DC AD
200 – 240V DC BD
12 – 14V DC RD
48 – 60V DC WD
Coil Voltage Suffix Code
Frame G
100 – 120V 50/60 Hz A
190 – 240V 50/60 Hz B
24V 50/60 Hz T
24 – 27V DC TD
480 – 500V 50/60 Hz C
380 – 440V 50/60 Hz L
42 – 48V 50/60 Hz W
110 – 130V DC AD
200 – 240V DC BD
48 – 60V DC WD
Frame L – N
110 – 250V 40 – 60 Hz/DC A
250 – 500V 40 – 60 Hz/DC C
48 – 110V 40 – 60 Hz/DC Y
24 – 48V DC TD
Frame L – N, S-Series
110 – 120V 50/60 Hz A
220 – 240V 50/60 Hz B
Frame P – R
220 – 250V 50 – 60 Hz/DC B
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . Page 47
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . Page 78
Discount Symbol . . . . . . . . . . . . . . . . . . . . . MC7