Technical data
Table Of Contents

June 2005
10
For more information visit: www.EatonElectrical.ca CAT.02.02.S.K.CD
XT IEC Power Control
Relays and Timers
Technical Data and Specifications
Table 12. Relays and Timers — Technical Data and Specifications (Continued)
Making and breaking conditions to DC13, time constant as stated.
See transparent overlay “Fuses” for time/current characteristics (please enquire).
Smoothed DC or three-phase bridge rectifier
Description XTRE XTCEXFAC_ XTRM XTMCXFA_
Contacts (Continued)
DC-13
DC-13 L/R ≤ 15 mS
Contacts in series:
1:24V
1:60V
2:60V
1:110V
3:110V
1:220V
3:220V
2.5
1
3
0.5
3
0.25
1
—
—
—
—
—
—
—
2.5
—
2.5
—
1.5
—
0.5
2.5
—
2.5
—
1.5
—
0.5
DC-13 L/R ≤ 50 mS
Contacts in series:
2:24V
3:24V
2:60V
3:60V
1:110V
3:110V
1:220V
3:220V
—
4
—
4
—
2
—
1
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Contact reliability Fault probability (λ)
(at U
e
= 24V DC, U
min
= 17, I
min
= 5.4 mA)
<10
-8
, < one failure in 10 million operations center
Conventional thermal current (I
th
)10101010
Short-circuit rating without welding
Maximum overcurrent protective device
220/240V – XTPR Frame B
380/415V – XTPR Frame B
Short-circuit protection, max. fuse
500V (a gG/gL)
500V (A fast)
4
4
10
—
—
—
10
—
4
4
6
10
4
4
6
10
Current heat losses at load of I
th
AC operated (W)
DC operated (W)
0.3
0.3
0.3
0.3
0.2
0.3
0.2
0.3
Magnet Systems
Pick-up and drop-out values
AC operated
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz (Pick-up x U
c
)
Dual-frequency coil 50/60 Hz (Pick-up x U
c
)
0.8 – 1.1
0.8 – 1.1
—
—
0.8 – 1.1
0.85 – 1.1
—
—
DC operated
Pick -up voltage (Pick-up x U
c
)
At 24V: without auxiliary contact module (40°C) (Pick-up x U
c
)
0.8 – 1.1
0.7 – 1.3
—
—
0.85 – 1.3
0.7 – 1.3
—
—
Power consumption
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
Pick-up VA
Pick-up W
24
19
—
—
25
22
—
—
Single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz
Sealing VA
Sealing W
4
1.2
—
—
4.6
1.3
—
—
Dual-frequency coil 50/60 Hz at 50 Hz
Pick-up VA
Pick-up W
28
22
—
—
30
26
—
—
Dual-frequency coil 50/60 Hz at 50 Hz
Sealing VA
Sealing W
4.6
1.4
—
—
5.4
1.6
—
—
Dual-frequency coil 50/60 Hz at 60 Hz
Pick-up VA
Pick-up W
26
21
—
—
29
24
—
—
Dual-frequency coil 50/60 Hz at 60 Hz
Sealing VA
Sealing W
3.9
1.2
—
—
3.9
1.2
—
—
DC operated
Pull-in = sealing (W) 3 — 2.6 —
Duty factor 100 — 100 —
Switching times at 100% U
c
(approximate values)
AC operated closing delay (mS)
AC operated make contact opening delay (mS)
AC operated with auxiliary contact module, max. closing delay (mS)
DC operated closing delay (mS)
DC operated make contact opening delay (mS)
DC operated with auxiliary contact module, max. closing delay (mS)
≤ 20
≤15
—
≤35
≤15
—
—
—
—
—
—
—
14 – 21
8 – 18
45
26 – 35
15 – 25
70
—
—
45
—
—
70