XT IEC Power Control XT IEC Power Control June 2005 Contents Description Page Relays and Timers Product Family Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
XT IEC Power Control June 2005 For more information visit: www.EatonElectrical.ca CAT.02.02.S.K.
XT IEC Power Control Relays and Timers 1 June 2005 Product Family Overview Product Description Contents Description Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . .
2 XT IEC Power Control Relays and Timers June 2005 Catalog Number Selection Catalog Number Selection Table 1. XT — Relay Catalog Numbering System XT RE C 10 B 22 AD Coil Code Product Line Prefix See Table 4 on Page 3.
XT IEC Power Control Relays and Timers 3 June 2005 Product Selection Product Selection Mini Control Relays Table 3.
XT IEC Power Control Relays and Timers 4 June 2005 Product Selection Table 5. Front Mount Auxiliary Contacts for use with XTRM Mini Control Relays Conventional free air thermal current, I th = I e , AC-1 in Amps Contact Configuration 10 0NO-2NC 10 1NO-1NC 10 2NO-0NC 10 1NO-1NC 10 0NO-4NC 10 1NO-3NC 10 2NO-2NC 10 3NO-1NC 10 4NO-0NC 10 2NO-2NC Contact Sequence 51 61 Package Qty.
XT IEC Power Control Relays and Timers 5 June 2005 Product Selection Control Relays Table 6.
XT IEC Power Control Relays and Timers 6 June 2005 Product Selection Table 8. Front Mount Auxiliary Contacts for Use with XTRE Control Relays Conventional Free Air Thermal Current, I th = I e , AC-1 in Amps Poles Contact Configuration Circuit Symbol 10 2 2NO 10 2 1NO-1NC 10 2 2NC 10 2 1NO-1NC 10 4 4NO 10 4 3NO-1NC 10 4 2NO-2NC 10 4 1NO-3NC 10 4 4NC 51 61 71 81 10 4 2NO-2NC 5765 71 83 53 63 Pkg. Qty.
XT IEC Power Control Relays and Timers 7 June 2005 Product Selection Mini Electronic On-Delay Timers Table 9. Mini Electronic On-Delay Timers Conventional Thermal Current I e (A) Rated Operational Current I e AC-11 Amps 220/230/240V 380/400/440V 6 3 3 6 3 6 Time Range Function Terminal Marking According to EN 50042 1.5 – 30 sec .05 – 1 sec 0.15 – 3 sec 0.5 – 10 sec 3 – 60 sec 0.15 – 3 min 0.5 – 10 min 3 – 60 min 0.15 – 3 h 0.
XT IEC Power Control Relays and Timers 8 June 2005 Product Selection Electronic Star-Delta (Wye-Delta) Table 11.
XT IEC Power Control Relays and Timers 9 June 2005 Technical Data and Specifications Technical Data and Specifications Table 12.
XT IEC Power Control Relays and Timers 10 June 2005 Technical Data and Specifications Table 12. Relays and Timers — Technical Data and Specifications (Continued) Description XTRE XTCEXFAC_ XTRM XTMCXFA_ 2.5 1 3 0.5 3 0.25 1 — — — — — — — 2.5 — 2.5 — 1.5 — 0.5 2.5 — 2.5 — 1.5 — 0.
XT IEC Power Control Relays and Timers 11 June 2005 Technical Data and Specifications Flow Diagrams — Electronic Timers XTMT Mini Timers Dimensions Mini Contactor Relays 5.5 [.22] A1-A2 15-18 t LED 58 [2.28 Figure 1. On-Delayed [1.77] OFF A1-A2 15-18 ON OFF LED – [2.05] – [2.13] Figure 7. Mini Control Relay XTRM — Approximate Dimensions in mm [in.] Figure 2. ON-OFF Function 43 [1.69] A1-A2 15-18 t LED 58 [2.28] Figure 3. Fleeting Contact on Energization A1-A2 15-18 t t t t 45 [1.
12 XT IEC Power Control Miniature Controls June 2005 Product Family Overview Contents Description Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . Non-reversing Mini Contactors . . . . . . . . . Reversing Mini Contactors . . . . . . . . . . . . . Star-Delta (Wye-Delta) Miniature Contactors . . . . Overload Relays. . . . . . . . . . Accessories . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . Dimensions . . . . . . . . .
XT IEC Power Control Miniature Controls 13 June 2005 Catalog Number Selection Catalog Number Selection Table 14.
XT IEC Power Control Miniature Controls 14 June 2005 Product Selection Product Selection Non-reversing Mini Contactors Table 16. Full Voltage Non-reversing Contactors with kW RATINGS Operational Current AC-3 Amp Rating 380/400V Conventional Free Air Thermal Current AC-1 at 50°C Maximum kW Ratings AC-3 3-Phase Motors 50 – 60Hz 220 – 380 – 550V 240V 400V No.
XT IEC Power Control Miniature Controls 15 June 2005 Product Selection Reversing Mini Contactors Table 19. Full Voltage Reversing Contactors with kW RATINGS Operational Current AC-3 Amp Rating 380/400V Conventional Maximum kW Ratings AC-3 Free Air Thermal 3-Phase Motors 50 – 60 Hz Current AC-1 at 220/230/240V 380/400/440V 50°C 500V 660/690V 6.6 20 1.5 3 3 3 33 34 34 8.8 20 2.
XT IEC Power Control Miniature Controls 16 June 2005 Product Selection Star-Delta (Wye-Delta) Miniature Contactors Table 22. Star-Delta (Wye-Delta) Miniature Contactor Configuration Maximum kW Ratings AC-3 Maximum 3-Phase Current Motor Rating Max. Changeover 1-Phase hp 3-Phase hp Ratings Time (sec.) Ratings 115V 200V 230V 200V 230V 460V 575V 3-Phase Motors 50 – 60 Hz 220/230/ 380/400/ 500V 240V 440V 4 5.5 5.
XT IEC Power Control Miniature Controls 17 June 2005 Product Selection Overload Relays Table 25. Mini Overload Relays Overload Release It Trip Class 0.1 – 0.16A 0.16 – 0.24A 0.24 – 0.4A 0.4 – 0.6A 10A 0.6 – 1A 1 – 1.6A 1.6 – 2.4A 10A 2.4 – 4A 4 – 6A 6 – 9A 9 – 12A 10A Contact Sequence 97 95 2 4 6 98 96 Contact Configuration Short Circuit Protection (A) Type 1 Type 2 Coordination, Coordination, gG/gL gG/gL Circuit Breaker CEC/NEC Fuse Catalog Number 1NO-1NC 20 20 20 20 0.
XT IEC Power Control Miniature Controls 18 June 2005 Accessories Accessories Auxiliary Contacts Front mounted snap-on auxiliary contacts for mini contactors are available with screw or spring cage terminals in a variety of contact configurations. Auxiliary contact modules are standard with interlocked opposing contacts, except in the case of earlymake or late-break contacts. Table 26.
XT IEC Power Control Miniature Controls 19 June 2005 Accessories RC Suppressor Star-Delta (WYE-Delta) Bridge Table 29. Star-Delta (WYE-Delta) Bridge Contact Sequence Package Catalog Qty. Number 20 Price XTMCXSDB Table 27. RC Suppressor Voltage 24 – 48 48 – 130 110 – 250 24 – 48 48 – 130 110 – 250 For Use With — Circuit Symbol XTMC6A…, A1 XTMC9A… XTMC6A…, XTMC9A… A2 XTMC6A…, XTMC9A… XTMCC6A…, XTMCC9A… XTMCC6A…, XTMCC9A… XTMCC6A…, XTMCC9A… Package Catalog Qty.
XT IEC Power Control Miniature Controls 20 June 2005 Accessories Reversing Link Kit Connector Table 34. Connector Table 32. Reversing Link Kit Description Main current wiring for reversing contactors and starters. Package Catalog Qty. Number 1 Price Description Package Catalog Qty. Number For mechanically arranging contactors and timing relays in combinations. 50 XTMCXRL Price XTMCXCN 0 mm distance between contactors.
XT IEC Power Control Miniature Controls 21 June 2005 Technical Data and Specifications Technical Data and Specifications Table 36. XT Miniature Controls — General Specifications Description XTMC6A… Coils A – Y XTMC9A… Coils AD – WD Coils A – Y XTMF9A… Coils AD – WD Coils A – Y 0.2 [0.44] 10,000,000 7 0.17 [0.
XT IEC Power Control Miniature Controls 22 June 2005 Technical Data and Specifications Table 37. XT Miniature Controls — Magnet Systems Description XTMC6A… Coils A – Y XTMC9A… Coils AD – WD Coils A – Y XTMF9A… Coils AD – WD Coils A – Y Coils AD – WD 0.8 – 1.1 0.85 – 1.1 — — — 0.8 – 1.1 0.8 – 1.1 0.85 – 1.1 — — — 0.8 – 1.1 0.8 – 1.1 0.85 – 1.1 — — — 0.85 – 1.
XT IEC Power Control Miniature Controls 23 June 2005 Technical Data and Specifications Table 38. XT Miniature Controls Description XTMC6A… Coils A – Y XTMC9A… Coils AD – WD Coils A – Y XTMF9A… Coils AD – WD Coils A – Y Coils AD – WD 22 20 19 50 22 20 19 50 22 20 19 50 22 20 19 50 22 20 19 60 22 20 19 60 Rated Operational Current, 50/60 Hz (Ie) in amperes (A) 220/230V 240V 380/400V 415V 440V 500V 660/690V 6.6 6.6 6.6 6.6 6.6 5 3.5 6.6 6.6 6.6 6.6 6.6 5 3.5 9.0 9.0 9.0 9.0 9.0 6.4 4.8 9.
24 XT IEC Power Control Miniature Controls June 2005 Technical Data and Specifications Table 40.
XT IEC Power Control Miniature Controls 25 June 2005 Technical Data and Specifications Electrical Switching Operation Charts 22 18.5 15 11 7.5 5.5 4 3 2.2 AC-3/400V A 58 43 36 30 23 16 12 8.8 XTMC 9A 6.5 XTMC 6A 5 XTMC DC Coil 1.5 3.5 1.1 2.5 XTMC AC Coil 0.8 0.55 2 1.6 0.01 kW 22 18.5 15 11 7.5 5.5 4 3 2.2 1.
XT IEC Power Control Miniature Controls June 2005 1400 1000 700 500 350 275 Short-time current Technical Data and Specifications Breaking current 26 AC-1/400V A 700 AC-1/400V 500 400 300 160 100 200 55 35 100 150 70 20 XTMC 9A XTMC 9A 50 40 10 7 5 4 3 2 30 20 15 1 0.1 0.2 0.3 0.5 0.7 1 2 3 5 7 10 Seconds 2 3 5 7 10 20 30 50 70 100 200 300 500 700 900 Duration of load Component lifespan (millions of operations) Figure 17.
XT IEC Power Control Miniature Controls 27 June 2005 Dimensions Dimensions D M4 62.5 [2.46] 58 50 [1.97] 45 [1.77] 35 [1.38] 45 [1.77] 52 [2.05] Figure 23. XTMCXRSA, XTMCXVSA Mini Suppressors — Approximate Dimensions in mm [in] D1 43 [1.69] Figure 19. Non-reversing Mini Contactor 45 [1.77] 58 [2.28] Table 41. Mini Contactor XTMC XTMCC D 52 [2.05] 54 [2.13] D1 83 [3.27] 86 [3.39] 45 [1.77] 69 [2.72] Figure 24. XTMCXTSA Mini Sealable Shroud — Approximate Dimensions in mm [in] 61 [2.
28 XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Product Family Overview Features and Benefits Contents Description Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection Non-reversing Contactors . . . Reversing Contactors . . . . . . . Non-reversing Starters . . . . . . Reversing Starters . . . . . . . . . . Star-Delta (Wye-Delta) Starters. . . . . . . . . . . . . . . . . . Overload Relays. . . . . . . . . . . . Accessories . . . . . . . . . . . . . . .
XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Catalog Number Selection Catalog Number Selection Table 42. XT IEC Contactors & Starters — Catalog Numbering System XT CE C 007 B 01 AD P16 Designation Maximum Overload Rating XT = XT Line of IEC Control XTAE, XTAS and XTAR Starters Only Frame B P16 = 0.1 – 0.16A P24 = 0.16 – 0.24A P40 = 0.24 – 0.4A P60 = 0.4 – 0.6A 001 = 0.6 – 1A 1P6 = 1.0 – 1.6A 2P4 = 1.6 – 2.4A 004 = 2.
XT IEC Power Control Contactors, Starters and Overload Relays 30 June 2005 Product Selection Product Selection Non-reversing Contactors Table 43. Full Voltage Non-reversing 3-Pole Contactors Ie (A) AC-3 AC-1 Maximum kW Maximum 3-Phase Motor Rating Ratings AC-3 3-Phase Motors 50 – 60 Hz 1-Phase hp Ratings 3-Phase hp Ratings 220/ 380/ 415V 660/ 1000V 115V 200V 230V 200V 230V 460V 230V 400V 690V Aux.
XT IEC Power Control Contactors, Starters and Overload Relays 31 June 2005 Product Selection Frame B Frame C Frame D Frame L Frame F – G Frame N Frame P Frame R Table 44.
XT IEC Power Control Contactors, Starters and Overload Relays 32 June 2005 Product Selection Table 46.
XT IEC Power Control Contactors, Starters and Overload Relays 33 June 2005 Product Selection Reversing Contactors Frame B XTCR Reversing Contactor Table 49.
XT IEC Power Control Contactors, Starters and Overload Relays 34 June 2005 Product Selection Table 50.
XT IEC Power Control Contactors, Starters and Overload Relays 35 June 2005 Product Selection Non-reversing Starters Frame C XTAE Non-reversing Starter Table 51.
XT IEC Power Control Contactors, Starters and Overload Relays 36 June 2005 Product Selection Table 52.
XT IEC Power Control Contactors, Starters and Overload Relays 37 June 2005 Product Selection Table 55. Overload Relay Suffix Motor Full Load Amperes Suffix Code For use with Contactor Amp Range Overload Relay Catalog Number Frame B P16 P24 P40 P60 7 – 15A 7 – 15A 7 – 15A 7 – 15A XTOBP16BC1 XTOBP24BC1 XTOBP40BC1 XTOBP60BC1 0.6 – 1 1 – 1.6 1.6 – 2.4 2.
XT IEC Power Control Contactors, Starters and Overload Relays 38 June 2005 Product Selection Reversing Starters Table 56. Full Voltage Reversing Starters with Screw Terminals Ie (A) Maximum kW Ratings AC-3 Maximum 3-Phase Motor Rating AC-3 3-Phase Motors 50 – 60 Hz 220/ 380/ 415V 660/ 230V 400V 690V 1-Phase hp Ratings 115V 230V Catalog Number 3-Phase hp Ratings 200V 230V 460V Price AC Coil DC Coil 575V Frame B 7 9 12 2.2 2.5 3.5 3 4 5.5 4 5.5 7 5 7.5 10 7.5 11 15 8 14.5 18 12.
XT IEC Power Control Contactors, Starters and Overload Relays 39 June 2005 Product Selection Table 58. Overload Relay Suffix Motor Full Load Amperes Suffix Code For use with Contactor Amp Range Overload Relay Catalog Number Frame B P16 P24 P40 P60 7 – 15A 7 – 15A 7 – 15A 7 – 15A XTOBP16BC1 XTOBP24BC1 XTOBP40BC1 XTOBP60BC1 0.6 – 1 1 – 1.6 1.6 – 2.4 2.
XT IEC Power Control Contactors, Starters and Overload Relays 40 June 2005 Product Selection Star-Delta (Wye-Delta) Starters Table 59. Star-Delta (Wye-Delta) Starters, 12 – 55A Ie (A) Maximum kW Ratings AC-3 Maximum 3-Phase current Motor Rating AC-3 3-Phase Motors 50 – 60 Hz 220/ 380/ 415V 500V 230V 400V 1-Phase hp Ratings 115V 230V 660/ 690V 3-Phase hp Ratings 200V 230V 460V 575V Maximum Changeover Time (sec) Components Description Catalog Number Frame B 12 3 5.5 7 5.5 5.
XT IEC Power Control Contactors, Starters and Overload Relays 41 June 2005 Product Selection Table 61. Star-Delta (Wye-Delta) Starters, 70 – 260A Ie (A) Maximum kW Ratings AC-3 Maximum 3-Phase current Motor Rating AC-3 3-Phase Motors 50 – 60 Hz 220/ 380/ 415V 500V 230V 400V 660/ 690V 1-Phase hp Ratings 115V 230V Maximum Changeover Time (sec) Components Description 70 18.
XT IEC Power Control Contactors, Starters and Overload Relays 42 June 2005 Product Selection Table 63.
XT IEC Power Control Contactors, Starters and Overload Relays 43 June 2005 Product Selection Table 65.
XT IEC Power Control Contactors, Starters and Overload Relays 44 June 2005 Product Selection Overload Relays Table 67.
XT IEC Power Control Contactors, Starters and Overload Relays 45 June 2005 Product Selection Table 68.
46 XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Product Selection Figure 29. Frame B — Overload Fitted Directly to the Contactor Figure 31. Frame C — Overload Mounted Separately from the Contactor Figure 33. Frame D — Overload Mounted Separately from the Contactor Figure 30. Frame C — Overload Fitted Directly to the Contactor Figure 32. Frame D — Overload Fitted Directly to the Contactor For more information visit: www.EatonElectrical.ca Figure 34.
XT IEC Power Control Contactors, Starters and Overload Relays 47 June 2005 Accessories Accessories Table 71. Full Voltage Non-reversing 3-Pole Contactors — Contact Sequence (Circuit Symbols) — Standard Offering Auxiliary Contacts Front mounted snap-on auxiliary contacts for XT contactors are available with screw or spring cage terminals in a variety of contact configurations.
XT IEC Power Control Contactors, Starters and Overload Relays 48 June 2005 Accessories Table 72. Front Mount Auxiliary Contacts (Continued) Conventional Free Air Thermal Current, Ith = Ie, AC-1 in Amps Poles Contact Configuration 10 2 2NO 13 23 10 2 1NO-1NC 53 61 10 2 1NO-1NC 10 2 2NC 10 4 4NO-0NC 13 23 33 43 10 4 3NO-1NC 13 21 33 43 10 4 2NO-2NC 10 4 2NO-2NC 53 61 71 83 10 4 1NO-3NC 13 21 31 41 10 4 0NO-4NC Circuit Symbol Pkg. Qty.
XT IEC Power Control Contactors, Starters and Overload Relays 49 June 2005 Accessories Table 73. Side Mount Auxiliary Contacts for Frame D – R, 40 – 2000A Conventional Free Air Thermal Current, Ith = Ie, AC-1 in Amps Poles Contact Configuration 10 2 1NO-1NC Circuit Symbol Pkg. Qty.
XT IEC Power Control Contactors, Starters and Overload Relays 50 June 2005 Accessories Mechanical Interlock Varistor Suppressor with Integrated LED Table 79. Mechanical Interlock A1 A2 Contact Sequence For use with … Pkg. Qty. Catalog Number XTCE007B – XTCE015B, XTCF020B 5 XTCEXMLB XTCE018C – XTCE032C XTCE040D – XTCE065D XTAE080F – XTCE150G 1 1 1 XTCEXMLC XTCEXMLD XTCEXMLG XTCE185L – XTCE500M 1 XTCEXMLM XTCE580N – XTCEC10N 1 XTCEXMLN Price Table 76.
XT IEC Power Control Contactors, Starters and Overload Relays 51 June 2005 Accessories Parallel Link Star-Delta (Wye Delta) Link Kits Table 82. Parallel Link For use with … Pkg. Qty. Catalog Number XTCE007B – XTCE015B 5 XTCEXPLKB XTCE018C – XTCE032C XTCE040D – XTCE065D XTCE080F – XTCE150G XTCE185L 5 XTCEXPLKC 1 XTCEXPLKD 1 XTCEXPLKG 1 XTCEXPLKL185 Price Main current wiring for star-delta (wye-delta) combinations. Includes the Star-Delta bridge. Table 85.
XT IEC Power Control Contactors, Starters and Overload Relays 52 June 2005 Accessories Incoming Terminal Terminal Flat Bar Table 88. Incoming Terminal For use with … Pkg. Qty. Catalog Number XTCE007B – XTCE015B 5 XTCEXITB Price For connection of a flat strip conductor. Comes with control circuit terminal (Consisting of 3 flat strip conductor terminals). Table 91. Terminal Flat Bar Price listed is for a quantity of one (1). Orders must be placed in multiples of package quantity listed.
XT IEC Power Control Contactors, Starters and Overload Relays 53 June 2005 Renewal Parts Renewal Parts Table 94.
54 XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Technical Data and Specifications Technical Data and Specifications Contents Description XT Contactors . . . . . . . . . . . . . Overload Relays . . . . . . . . . . . . Coil Data . . . . . . . . . . . . . . . . . . Auxiliary Contacts . . . . . . . . . . AC Ratings . . . . . . . . . . . . . . . . DC Ratings . . . . . . . . . . . . . . . . Heat Loss . . . . . . . . . . . . . . . . . Life Curves . . . . . . . . . . . . . . . .
XT IEC Power Control Contactors, Starters and Overload Relays 55 June 2005 Technical Data and Specifications Table 98. XT Contactors Technical Data and Specifications — Frame B (Continued) Description XTCE007B XTCE009B XTCE012B XTCE015B 1 x (0.75 – 4) 2 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 18 – 14 1 x (0.75 – 4) 2 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 18 – 14 1 x (0.75 – 4) 2 x (0.75 – 2.5) 1 x (0.75 – 2.5) 1 x (0.75 – 2.5) 18 – 14 1 x (0.75 – 4) 2 x (0.75 – 2.5) 1 x (0.
56 XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Technical Data and Specifications Frame C – D Table 99.
XT IEC Power Control Contactors, Starters and Overload Relays 57 June 2005 Technical Data and Specifications Table 99.
XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Technical Data and Specifications Table 100. XT Contactors Technical Data and Specifications — Frame F – G (Continued) Description XTCE080F XTCE095F XTCE115G XTCE150G — 1 x (4 – 70) 2 x (4 – 50) 1 x (16 – 95) 2 x (16 – 70) 10 – 4/0 2 x (6 x 16 x 0.8) — 1 x (4 – 70) 2 x (4 – 50) 1 x (16 – 95) 2 x (16 – 70) 10 – 4/0 2 x (6 x 16 x 0.8) — 1 x (10 – 95) 2 x (10 – 70) 1 x (16 – 120) 2 x (16 – 95) 8 – 250 MCM 2 x (6 x 16 x 0.
XT IEC Power Control Contactors, Starters and Overload Relays 59 June 2005 Technical Data and Specifications Frame L – M Table 101. XT Contactors Technical Data and Specifications — Frame L – M Description XTCE185L XTCE225L XTCE250L XTCE300M XTCE400M 6.5 [14.3] 10,000,000 6.5 [14.3] 10,000,000 IEC/EN 60947, VDE 0660, UL, CSA 6.5 [14.
XT IEC Power Control Contactors, Starters and Overload Relays 60 June 2005 Technical Data and Specifications Table 101.
XT IEC Power Control Contactors, Starters and Overload Relays 61 June 2005 Technical Data and Specifications Frame N – R Table 102.
XT IEC Power Control Contactors, Starters and Overload Relays 62 June 2005 Technical Data and Specifications Table 102.
XT IEC Power Control Contactors, Starters and Overload Relays 63 June 2005 Technical Data and Specifications Coil Data Frame B – D Table 104. Coil Data — Frame B – D XTCE007B XTCE009B XTCE012B XTCE015B XTCE018C XTCE025C XTCE032C XTCE040D XTCE050D XTCE065D Voltage Tolerance Pick-Up (x Uc) AC operated DC operated Drop-Out (x Uc) AC operated DC operated 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.1 0.8 – 1.11 0.8 – 1.11 0.8 – 1.11 0.
XT IEC Power Control Contactors, Starters and Overload Relays 64 June 2005 Technical Data and Specifications Frames F – G Table 105. Coil Data — Frames F – G XTCE80F XTCE95F XTCE115G XTCE150G 0.8 – 1.1 0.7 – 1.2 0.8 – 1.1 0.7 – 1.2 0.8 – 1.1 0.7 – 1.2 0.8 – 1.1 0.7 – 1.2 0.3 – 0.6 0.15 – 0.6 0.3 – 0.6 0.15 – 0.6 0.3 – 0.6 0.15 – 0.6 0.3 – 0.6 0.15 – 0.6 310 165 310 165 130 130 130 130 26 5.5 26 5.5 3.5 2 3.5 2 375 190 31 6.8 375 190 31 6.8 130 130 3.5 2 130 130 3.
XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Technical Data and Specifications Frames L – R Table 106. Coil Data — Frames L – R Description XTCE185L XTCE225L, XTCE250L XTCE300M, XTCE400M XTCE500M Voltage Tolerance Pick-Up (x Uc) XTCE185L – XTCEC20R XTCS185L – XTCS500M Drop-Out (x Uc) XTCE185L – XTCEC20R XTCS185L – XTCS500M 0.7 x Ucmin — 1.15 x Ucmax 0.85 x Ucmin — 1.1 x Ucmax 0.2 x Ucmin — 0.6 x Ucmax 0.2 x Ucmin — 0.
XT IEC Power Control Contactors, Starters and Overload Relays 66 June 2005 Technical Data and Specifications Table 106. Coil Data — Frames L – R (Continued) Description XTCE580N XTCE750N, XTCE820N XTCEC10N XTCEC14P XTCEC20R Voltage Tolerance Pick-Up (x Uc) XTCE185L – XTCEC20R XTCS185L – XTCS500M Drop-Out (x Uc) XTCE185L – XTCEC20R XTCS185L – XTCS500M 0.7 x Ucmin — 1.15 x Ucmax 0.85 x Ucmin — 1.1 x Ucmax 0.2 x Ucmin — 0.6 x Ucmax 0.2 x Ucmin — 0.
XT IEC Power Control Contactors, Starters and Overload Relays 67 June 2005 Technical Data and Specifications Overload Relays Tripping time depends on response current. With devices at operating temperature, the tripping time of the overload relay reduces to approximately 25% of the read off value. Specific characteristics for each individual setting range can be found in MN03402001E.
XT IEC Power Control Contactors, Starters and Overload Relays 68 June 2005 Technical Data and Specifications Table 107. Overload Relay — Technical Data and Specifications (Continued) Description XTOB…BC1, XTOB…CC1 XTOB…DC1 6000 III/3 6000 III/3 2 x (0.75 – 4) 2 x (0.75 – 2.5) 2 x (18 – 12) M3.5 2 x (0.75 – 4) 2 x (0.75 – 2.5) 2 x (18 – 12) M3.5 0.8 – 1.3 7 – 11.5 0.8 – 1.3 7 – 11.5 Size 2 1x6 500 500 Size 2 1x6 500 500 240 6 240 6 1.5 1.5 0.5 0.5 1.5 1.5 0.5 0.5 1.5 1.5 0.9 0.8 1.5 1.5 0.
XT IEC Power Control Contactors, Starters and Overload Relays 69 June 2005 Technical Data and Specifications Auxiliary Contacts Table 108. Auxiliary Contacts Technical Data and Specifications Description XTCE007B…– XTCE032C XTCEXFAC… XTCEXFCC… XTCEXFAG… XTCEXSBLN… XTCEXSBN… XTCEXSBNC...
XT IEC Power Control Contactors, Starters and Overload Relays 70 June 2005 Technical Data and Specifications AC Ratings Table 109.
XT IEC Power Control Contactors, Starters and Overload Relays 71 June 2005 Technical Data and Specifications Table 109.
XT IEC Power Control Contactors, Starters and Overload Relays 72 June 2005 Technical Data and Specifications Table 109.
XT IEC Power Control Contactors, Starters and Overload Relays 73 June 2005 Technical Data and Specifications Table 109.
74 XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Technical Data and Specifications DC Ratings Table 110. DC Ratings — DC-1 Description Rated operation current {1} (Ie) in amperes 60V 110V 220V 440V XTCE007B XTCE009B XTCE012B XTCE015B XTCE018C XTCE025C XTCE032C 20 20 15 1 20 20 15 1.3 20 20 15 1.3 20 20 15 1.3 35 35 35 2.9 40 40 40 2.9 40 40 40 2.9 XTCE040D XTCE050D XTCE065D XTCE080F XTCE095F XTCE115G XTCE150G 60V 110V 220V 440V 50 50 45 2.9 60 50 45 2.
XT IEC Power Control Contactors, Starters and Overload Relays 75 June 2005 Technical Data and Specifications Table 112. DC Ratings — DC-5 Description Rated operation current {1} (Ie) in amperes 60V 110V 220V 440V XTCE007B XTCE009B XTCE012B XTCE015B XTCE018C XTCE025C XTCE032C 20 20 1.5 0.2 20 20 1.5 0.2 20 20 1.5 0.2 20 20 1.5 0.2 35 35 10 0.6 35 35 10 0.6 40 40 25 0.6 XTCE040D XTCE050D XTCE065D XTCE080F XTCE095F XTCE115G XTCE150G 50 50 25 0.6 60 50 25 0.6 72 72 35 0.
XT IEC Power Control Contactors, Starters and Overload Relays 76 June 2005 Technical Data and Specifications Life Curves 5.5 4 3 XTCE065D XTCE050D XTCE040D XTCE032C XTCE025C 18 XTCE018C 12 9 7 0.01 XTCE012B XTCE009B XTCE007B 0.02 0.4 0.6 1 0.04 0.06 0.1 0.2 2 4 Component Lifespan [Millions of Operations] 6 A 4 2.2 2.2 1.5 45 37 30 145 104 85 72 58 43 36 15 30 11 7.5 23 16 0.01 0.4 0.6 1 0.2 2 4 0.02 0.04 0.06 0.
XT IEC Power Control Contactors, Starters and Overload Relays 77 June 2005 Technical Data and Specifications 1400 900 1000 850 800 700 500 400 350 300 275 XTCEC14P A 10000 XTCE820N XTCEC10N, XTCEC14P, XTCEC20R XTCE750N 8000 XTCE650N XTCE580N 6000 AC-1/400 V XTCE820N/XTCEC10N XTCE750N XTCE650N XTCE580N XTCE500M XTCE400M XTCE500M 5000 XTCE400M 4000 XTCE300M XTCE250M XTCE225L XTCE300M XTCE185L Short-Time Current Breaking Current A 160 100 55 35 3000 XTCE250M 2500 2000 XTCE185L/XTCE225L 1500 10
78 XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Dimensions Dimensions XTCE Contactors 36 [1.42] 4 x M4 Dia. 68 [2.68] [.71] 8.7 [.34] Typ. 60 [2.36] 45 [1.77] 3.2 [.13] 35 [1.38] 6.5 [.26] 5.1 [.20] 75 [2.95] 45 [1.77] 116.3 [4.58] Figure 43. Frame B, XTCE007B – XTCE015B Contactors with Screw Terminals (7 – 15A) — Approximate Dimensions in mm [in] 26.4 [1.04] 68 [2.68] 4 x M4 Dia. 52.3 [2.06] 1.8 [.07] 1.8 [.07] 60 [2.36] 3.2 [.13] 6.5 [.26] 35 [1.38] 75 [2.
XT IEC Power Control Contactors, Starters and Overload Relays 79 June 2005 Dimensions 4 x M4 Dia. 104 [4.09] 57 [2.24] 86.4 [3.40] 105 [4.13] 45 [1.77] 34.4 [1.35] 4.7 [.19] 55 [2.17] 6.9 [.27] 113.8 [4.48] 132.1 [5.20] 146.8 [5.78] Figure 46. Frame D, XTCE040D – XTCE065D Contactors (40 – 65A) — Approximate Dimensions in mm [in] 26.4 40 123.9 170 [1.04] [1.57] [4.88] [6.69] 30 [1.18] 10 [.39] 30 [1.18] 4.0 [.18] 159 [6.26] 174.4 [6.87] 90 [30.54] Figure 47.
80 XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Dimensions W1 W 11 [.43] Dia. M6 Dia. H3 H1 H H2 W3 W2 D1 W4 140 [5.51] 8 [.31] D Figure 48. Frame L – M, XTCE185L – XTCE500M Contactors (185 – 500A) — Approximate Dimensions in mm [in] Table 114. Frame L – M, XTCE185L – XTCE500M Contactors (185 – 500A) — Approximate Dimensions in mm [in] W W1 W2 W3 W4 H H1 H2 H3 D D1 Frame L (185 – 250A) 140 [5.51] 160 [6.30] 120 [4.72] 20 [.79] 48 [1.89] 180 [7.
XT IEC Power Control Contactors, Starters and Overload Relays 81 June 2005 Dimensions M6 Dia. 210 342 [13.46] 232 [9.13] 256 [10.08] 215 [8.46] 308 [12.13] 165 [6.50] 60 [2.36] 100 [3.94] 130 [5.12] Dia. 100 [3.94] 10 [.39] 232 [9.13] 260 [10.24] Figure 50. Frame P, XTCEC14P Contactor (1400A, AC-1) — Approximate Dimensions in mm [in] 210 [8.27] 392 [15.43] 300 272 [11.81] 10.71] 352 [13.86] 150 [5.91] 252 [9.92] 40 [1.57] 80 [3.15] 80 [3.15] 150 [5.90] 125 [4.92] 14 [.55] Dia. 172.
82 XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Dimensions XTAE Starters 45.3 [1.78] 35 [1.38] Mounting Holes for M4 or #8 Screws (4 Places) 117.1 [4.61] 75.8 [2.98] 60 [2.36] 45 [1.77] Mounting Holes for M4 or #8 Screws (4 Places) 146 [5.75] 132.5 [5.22] 60 [2.36] 117.8 [4.64] 105 [4.13] 174 [6.85] 83.3 [3.28] 88.4 [3.48] To Reset Figure 52. Frame B, XTAE007B – XTAE012B Starters (7 – 12A) 45 [1.77] 35 [1.38] Mounting Holes for M4 or #8 Screws (2 Places) 98 [3.
XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Dimensions 90 [3.54] 70 [2.76] 160 [6.30] 150 [5.91] 170 57 [2.24] [6.69] 156 [6.14] 277 [10.91] 91 [3.58] 74 [2.91] 95 [3.74] 100 [3.94] 118 [4.65] 7 [.276] Dia. 134 [5.28] Figure 55. Frames F – G, XTAE080F – XTAE150G Starters (80 – 150A) — Approximate Dimensions in mm [in] 150 [5.91] 110 [4.33] 523 [20.60] 328 [12.91] 34 [1.34] ~144 [5.67] Figure 56.
XT IEC Power Control Contactors, Starters and Overload Relays 84 June 2005 Dimensions Reversing Combination H W D Figure 57. Reversing Combination — Approximate Dimensions in mm [in] Table 116. Reversing Combination — Approximate Dimensions in mm [in] Frame B (7 – 15A) Frame C (18 – 32A) Frame D (40 – 65A) Frame F – G (80 – 150A) W H D W H D W H D W H D 90 [3.54] 68 [2.68] 125.2 [4.93] 90 [3.54] 85 [3.34] 147.3 [5.80] 110 [4.33] 115 [4.53] 146.8 [5.78] 180 [7.09] 170 [6.
XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Dimensions D1 42.5 [1.67] H 5 [.20] D2 16.5 [.65] D W Figure 60. Frame B – C, XTOBXDINC DIN Rail or Panel Mount Adapter and Frame D, XTOBXDIND DIN Rail or Panel Mount Adapter — Approximate Dimensions in mm [in] Table 117. XTOBXDINC, XTOBXDIND — Approximate Dimensions in mm [in] H W D D1 XTOB…CC1 85 [3.46] 45 [1.77] 90.5 [3.56] 58.3 [2.30] 3.8 [.15] XTOB…DC1 86 [3.39] 60 [2.36] 112 [4.41] 80.5 [3.17] 4.7 [.
XT IEC Power Control Contactors, Starters and Overload Relays June 2005 Dimensions 110 [4.33] 121 [4.76] 144 [5.67] 96 [3.78] 48 [1.89] 111 [4.37] 144 [5.67] ** 74 [2.91] * 86 7 [.28] 5* 25 [.20] [.98] 94 [3.70] 169 [6.65] 7 [.28] Dia. ** 16.5 [.65] * = OFF ** = RESET/ON 11 [.43] Dia. 128 [5.04] Figure 62. Frame L, XTOB…LC1 Overload Relay — Approximate Dimensions in mm [in] Current Transformer Operated Overload Relay 185 [7.28] 8 [.31] 4.3 [.17] 185 [7.28] 1.5 [.06] 7.5 [.30] 21 [.
XT IEC Power Control Contactors, Starters and Overload Relays 87 June 2005 Dimensions Mechanical Interlock Suppressor 15 [.59] 32 [1.26] Approx. 28 [1.10] 9.2 [.36] Figure 64. Frame L – M. XTCEXMLM Mechanical Interlock — Approximate Dimensions in mm [in] 9 [.35] 25 [.98] Figure 67. Suppressor — Approximate Dimensions in mm [in] 20 [.79] 515 [20.28] 430 [16.93] Cable Terminal Block 270 [10.63] 300 [11.81] H 9 [.35] 135 [5.31] Figure 65.
88 XT IEC Power Control Contactors and Starters — Enclosed Control June 2005 Product Family Overview Contents Description Cover Control . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . Modification Codes . . . . . . . . .
XT IEC Power Control Contactors and Starters — Enclosed Control 89 June 2005 Product Family Overview Cover Control Non-combination Starters Current Power Transformer (CPT) may be required. Combination Starters ■ ■ ■ ■ ■ Cover control for Combination Starters uses E22 style (22 mm). Selector switches are maintained with lever operators. Pushbuttons are momentary type with extended pushbutton. The kit includes hardware and connecting wires (where possible).
XT IEC Power Control Contactors and Starters — Enclosed Control 90 June 2005 Catalog Number Selection Catalog Number Selection Table 122.
XT IEC Power Control Contactors and Starters — Enclosed Control 91 June 2005 Product Selection Table 124.
XT IEC Power Control Contactors and Starters — Enclosed Control 92 June 2005 Product Selection Table 125.
XT IEC Power Control Contactors and Starters — Enclosed Control 93 June 2005 Product Selection Table 126.
XT IEC Power Control Contactors and Starters — Enclosed Control 94 June 2005 Product Selection Table 127.
XT IEC Power Control Contactors and Starters — Enclosed Control 95 June 2005 Product Selection Table 128.
XT IEC Power Control Contactors and Starters — Enclosed Control 96 June 2005 Product Selection Table 129.
XT IEC Power Control Contactors and Starters — Enclosed Control 97 June 2005 Product Selection Table 130. Class 19 — XT FVNR Combination with Fused Disconnect (Type 1 and Type 4X) Amps Maximum hp (kW Ratings AC-3) 1-Phase Motor Voltage Coil Voltage @ 60 Hz Fuse Clips 3-Phase Type 4X/IP66 Type 1/IP23 Catalog Number Price Catalog Number Component Price Catalog Number Frame B 7 — 115 200 230 380 460 575 — — — 1-1/2 2 (2.
XT IEC Power Control Contactors and Starters — Enclosed Control 98 June 2005 Product Selection Table 130.
XT IEC Power Control Contactors and Starters — Enclosed Control 99 June 2005 Product Selection Table 131. Class 19 — XT FVNR Combination with Fused Disconnect (Type 4X Nonmetallic and Type 12) Amps Maximum hp (kW Ratings AC-3) 1-Phase Motor Voltage Coil Voltage @ 60 Hz Fuse Clips 3-Phase Type 4X Nonmetallic/IP66 Type 12/IP65 Catalog Number Catalog Number Price Component Price Catalog Number Frame B 7 — 115 200 230 380 460 575 — 1/4 3/4 1 — — — — — 1-1/2 2 (2.
XT IEC Power Control Contactors and Starters — Enclosed Control 100 June 2005 Product Selection Table 131.
XT IEC Power Control Contactors and Starters — Enclosed Control 101 June 2005 Product Selection Table 132. Class 20 — XT FVR Combination with Fused Disconnect (Type 1 and Type 4X) Amps Maximum hp (kW Ratings AC-3) 1-Phase Motor Voltage Coil Voltage @ 60 Hz Fuse Clips 3-Phase Type 4X/IP66 Type 1/IP23 Catalog Number Price Catalog Number Component Price Catalog Number Frame B 7 — 115 200 230 380 460 575 — — — 1-1/2 2 (2.
XT IEC Power Control Contactors and Starters — Enclosed Control 102 June 2005 Product Selection Table 132.
XT IEC Power Control Contactors and Starters — Enclosed Control 103 June 2005 Product Selection Table 133. Class 20 — XT FVR Combination with Fused Disconnect (Type 4X Nonmetallic and Type 12) Amps Maximum hp (kW Ratings AC-3) 1-Phase Motor Voltage Coil Voltage @ 60 Hz Fuse Clips 3-Phase Type 4X Nonmetallic/IP66 Type 12/IP65 Catalog Number Catalog Number Price Component Price Catalog Number Frame B 7 — 115 200 230 380 460 575 — 1/4 3/4 1 — — — — — 1-1/2 2 (2.
XT IEC Power Control Contactors and Starters — Enclosed Control 104 June 2005 Product Selection Table 133.
XT IEC Power Control Contactors and Starters — Enclosed Control 105 June 2005 Product Selection Table 134. Class 25 — XT FVNR with HMCP/E (Type 1 and Type 4X) Amps Maximum hp (kW Ratings AC-3) 1-Phase Motor Voltage Coil Voltage @ 60 Hz HMCPE 3-Phase Type 4X/IP66 Type 1/IP23 Catalog Number Price Catalog Number Component Price Catalog Number Frame B 7 — 115 200 230 380 460 575 — — — 1-1/2 2 (2.
XT IEC Power Control Contactors and Starters — Enclosed Control 106 June 2005 Product Selection Table 134.
XT IEC Power Control Contactors and Starters — Enclosed Control 107 June 2005 Product Selection Table 135. Class 25 — XT FVNR with HMCP/E (Type 4X Nonmetallic and Type 12) Amps Maximum hp (kW Ratings AC-3) 1-Phase Motor Voltage Coil Voltage @ 60 Hz HMCPE 3-Phase Type 4X Nonmetallic/IP66 Type 12/IP65 Catalog Number Catalog Number Price Component Price Catalog Number Frame B 7 — 115 200 230 380 460 575 — — — 1-1/2 2 (2.
XT IEC Power Control Contactors and Starters — Enclosed Control 108 June 2005 Product Selection Table 135.
XT IEC Power Control Contactors and Starters — Enclosed Control 109 June 2005 Product Selection Table 136. Class 26 — XT FVR Combination with HMCP/E (Type 1 and Type 4X) Amps Maximum hp (kW Ratings AC-3) 1-Phase Motor Voltage Coil Voltage @ 60 Hz HMCPE 3-Phase Type 4X/IP66 Type 1/IP23 Catalog Number Price Catalog Number Component Price Catalog Number Frame B 7 — 115 200 230 380 460 575 — 1/4 3/4 1 — — — — — 1-1/2 2 (2.
XT IEC Power Control Contactors and Starters — Enclosed Control 110 June 2005 Product Selection Table 136.
XT IEC Power Control Contactors and Starters — Enclosed Control 111 June 2005 Product Selection Table 137. Class 26 — XT FVR Combination with HMCP/E (Type 4X Nonmetallic and Type 12) Amps Maximum hp (kW Ratings AC-3) 1-Phase Motor Voltage Coil Voltage @ 60 Hz HMCPE 3-Phase Type 4X Nonmetallic/IP66 Type 12/IP65 Catalog Number Catalog Number Price Component Price Catalog Number Frame B 7 — 115 200 230 380 460 575 — — — 1-1/2 2 (2.
XT IEC Power Control Contactors and Starters — Enclosed Control 112 June 2005 Product Selection Table 137.
XT IEC Power Control Contactors and Starters — Enclosed Control 113 June 2005 Wiring Diagrams Wiring Diagrams With 3-Position Selector Switch FVNR with Pushbutton Control Hand M 01 L1 02 L2 03 L3 OL T1 OFF 2/3 1 T2 A1 M M A2 3/4 Motor Auto T3 Remote Auto Contact Motor Run Control Power Transformer Option Start Stop A1 1 M 2/3 61 M 3/4 A2 95 M OL M 96 Motor Stopped 62/7 97 OL 01 L1 02 L2 03 L3 OL Overload Tripped 98 96 1 Reversing Combination Starter Wiring R
114 XT IEC Power Control Contactors and Starters — Enclosed Control June 2005 Wiring Diagrams Remote Pilot Devices Connections for Non-reversing Starter 2-Wire Control Figure 1 Front View of Panel 3/14 1 AC Lines 3 5 1 L3 L1 L2 Not for Use with Auto Reset OL Relays 3-Wire Control 1 A1 Start A2 2/13 M 3/14 2/13 1 Stop “C” 3/14 98 When More Than One Pushbutton Station is Used, Omit Connector “A” and Connect per Sketch Below Start 97 96 OL 2/ T1 Start Reset 4/ T2 6/ T3 95 3/14 Stop S
XT IEC Power Control Contactors and Starters — Enclosed Control 115 June 2005 Wiring Diagrams SPDT Switch For 3 1 Wire “F” – Used with Local Control Pushbuttons 5 4 Figure 1 Front View of Panel Remote Control Stations Hold Down Pushbutton For 3 Rev 1 5 AC 3 2 Lines 1 3 5 L1 L2 L3 53 Auxiliary 61 Contact Reversing Starter Elementary Diagram Lines L1 L2 L3 Contactors “F” and “R” are Mechanically Interlocked F 53 R 54 62 54 62 5 Rev OL 61 F T1 OL T2 T3 R 1 Pushbutton For Rev A1 A2
116 XT IEC Power Control Contactors and Starters — Enclosed Control June 2005 Dimensions Dimensions Enclosure Boxes NEMA 1, 3R, 4, 4X, 12 XT HMCP/E Combination Starters Table 143. Class 25: FVNR Combination with HMCP/E and CPT NEMA 1, 3R, 4, 4X, 12 XT Non-combination Starters Table 138. Class 09 — FVNR Starters (Non-combination) IEC Size (Frame / Amps) Box Number Ship Weight in kg [Lb] B – H / 7 – 32A B – H / 7 – 32A 5A 5P 6.4 [14] 4.5 [10] J – L/40 – 65A J – L/40 – 65A 5A 5P 7.0 [16] 5.
XT IEC Power Control Contactors and Starters — Enclosed Control 117 June 2005 Modification Codes Modification Codes Table 145. A — Ammeters, Auxiliary Contacts (Continued) Modification Table 145.
XT IEC Power Control Contactors and Starters — Enclosed Control 118 June 2005 Modification Codes Table 147. C — Control Power Transformer, IT.
XT IEC Power Control Contactors and Starters — Enclosed Control 119 June 2005 Modification Codes Table 148. D — Device Labels, Drain and Breather, DeviceNet Modification Catalog Number Suffix Description Device Labels D1 (each label) Drain and Breather (Type 7/9 Enclosure) D5 Drain and Breather D6 D7 Drain Only Breather Only DeviceNet D9 DN65 Table 151.
XT IEC Power Control Contactors and Starters — Enclosed Control 120 June 2005 Modification Codes Table 155.
XT IEC Power Control Contactors and Starters — Enclosed Control 121 June 2005 Modification Codes Table 156. Q — IQ Products Modification IQ Products IQ Data Metering Module Catalog Number Suffix Description Q14 IQ 220 with cable Q1 IQ 500 Q3 MP3000 Q5 IQ 4000 Q12 IQ Data Metering Module Q14 IQ 220 with Cable Adder Table 158.
XT IEC Power Control Contactors and Starters — Enclosed Control 122 June 2005 Modification Codes Table 159.
XT IEC Power Control Manual Motor Protectors 123 June 2005 Product Family Overview Contents Manual Motor Protectors Description The XTPB and XTPR MMPs are UL Listed under UL 508 as Manual Motor Controllers. They provide an economical solution for applications requiring simple manual starting and stopping of motors. When used as an MMP, they are typically installed in an enclosure. Many enclosures are offered as accessories for the MMPs.
XT IEC Power Control Manual Motor Protectors 124 June 2005 Product Family Overview Features ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ON/OFF Rotary Handle with Lockout Provision Visible Trip Indication Class 10 Overload Protection Phase Loss Sensitivity Ambient Temperature Compensation to IEC/EN 60947, VDE 0660 Fixed Short Circuit Trip — 14 times maximum setting of overload FLA dial Type 2 Coordination per IEC 947 Identification Markers Standard on Starter Faceplate Motor Applications from 0.
XT IEC Power Control Manual Motor Protectors 125 June 2005 Product Family Overview MMP with XTPAXSATR20 Signalling switch. Separate “Short-Circuit” and “Tripped” signals. Interruption of MMPs by means of pushbutton or EMERGENCY-STOP button in the system. L1 L2 L3 N L1 L2 L3 N F1 Max. 10A F1 Max. 10A 1 3 5 F2 Max. 10A H1 H2 4.43 1 4.13 3 5 D1 07 U 2 4 Q1 4.44 6 4.
126 XT IEC Power Control Manual Motor Protectors June 2005 Catalog Number Selection Catalog Number Selection Table 163. XT— Catalog Numbering System XT PR 012 B C1 Designation Trip Class XT = XT IEC Power Control C1 = Class 10 Blank = Magnetic only (No thermal trip) Type PB = PR = PM = PT = Frame Size Manual Motor Protector — Pushbutton Manual Motor Protector — Rotary Manual Motor Protector — Magnetic Only Manual Transformer Protector (High Mag.
XT IEC Power Control Manual Motor Protectors 127 June 2005 Product Selection Product Selection Product Selection for Manual Motor Starter Applications When ordering, specify Catalog Numbers according to the following stipulations: XT Manual Motor Protectors are selected based on the overload current range required for a given motor. This current range is determined from the motor Full Load Ampere rating and Motor Service Factor usually found on the motor nameplate.
XT IEC Power Control Manual Motor Protectors 128 June 2005 Product Selection B-Frame D-Frame Table 165. XTPR Rotary Manual Motor Protectors with Screw Terminals — Global Ratings and North American Ratings Type 1 and Type 2 Coordination Motor Protective Device with Thermal and Magnetic Trip Rated Uninterrupted Current — Iu = Ie (Amps) Maximum Motor Ratings FLA Adjustment Range / Overload Release — Ir (Amps) Short Circuit Release — Irm (Amps) 0.1 – 0.16 0.16 – 0.25 0.25 – 0.4 0.4 – 0.63 0.
XT IEC Power Control Manual Motor Protectors 129 June 2005 Product Selection Table 166.
XT IEC Power Control Manual Motor Protectors 130 June 2005 Product Selection B-Frame D-Frame Table 168.
XT IEC Power Control Manual Motor Protectors 131 June 2005 Product Selection B-Frame Table 169. XTPT Transformer Protective Circuit Breakers — Global and North American Ratings Type 1 and Type 2 Coordination For the protection of transformers with a high inrush current. Fixed short-circuit trip of 15 – 22 times max.
XT IEC Power Control Manual Motor Protectors 132 June 2005 Product Selection B-Frame Table 170. XTPM Motor Protective Circuit Breakers for Starter Combinations — Global Ratings Type 1 and Type 2 Coordination Motor Protective Device without Overload Function Rated Uninterrupted Current — Iu (Amps) FLA Adjustment Range / Overload Release — Ir (Amps) Short Circuit Release — Irm (Amps) — — — — — — — — — — — — — — — 2.2 3.5 5.6 8.
XT IEC Power Control Manual Motor Protectors 133 June 2005 Accessories Accessories Auxiliary Contacts Side-Mount Auxiliary Contacts Table 171. Side-Mount Auxiliary Contacts Contact Configuration Contact Sequence 1NO-1NC 1.13 1.21 Screw Terminals Catalog Pkg. Qty. Number Spring Cage Terminals Pkg. Catalog Qty. Number 1 XTPAXSA11 5 XTPAXSAC11 1 XTPAXSA12 — — 1 XTPAXSA21 — — Price L1L2 L3 1.14 1.22 1NO-2NC 1.131.21 1.31 L1L2 L3 1.14 1.22 1.32 2NO-1NC 1.131.21 1.
XT IEC Power Control Manual Motor Protectors 134 June 2005 Accessories Side-Mount Trip Indicating Auxiliary Contacts Shunt Release C1 Contact Sequence C2 Table 175. Shunt Release Table 173. Side-Mount Trip Indicating Auxiliary Contacts Contact Configuration Contact Sequence 2 x 1NO “+” “ ” 4.43 4.13 Pkg. Catalog Qty. Number 2 XTPAXSATR20 2 XTPAXSATR02 Price 4.44 4.14 On/Off L1L2 L3 “+” “ >” Trip “+” L1L2 L3 “+” “ >” 2 x 1NC “+” “ ” 4.31 4.
XT IEC Power Control Manual Motor Protectors 135 June 2005 Accessories Current Limiter IP65 Rotary Handle Mechanism Table 177. Current Limiter Description Contact Sequence To enhance the switching capacity of noninherently safe 16 – 25A Manual Motor Protectors to 150 kA/ 440V Pkg. Qty. Catalog Number Price 1 XTPAXCL L Table 180. IP65 Rotary Handle Mechanism T Max. rated operation voltage Ue = 690V, rated uninterrupted current Iu = 63A. Can be used for individual and group protection.
XT IEC Power Control Manual Motor Protectors 136 June 2005 Accessories Indicating Lights Table 183. Indicating Lights Color Description — Indicating Light Pkg. Qty. Catalog Number White 110 – 230V 230 – 240V 415 – 500V 10 10 10 XTPAXILWB XTPAXILWN XTPAXILWC Green 110 – 230V 230 – 240V 415 – 500V 10 10 5 XTPAXILGB XTPAXILGN XTPAXILGC Price Color Description — Indicating Light Pkg. Qty.
XT IEC Power Control Manual Motor Protectors 137 June 2005 Accessories Shroud for Unused Terminals Table 185. Shroud for Unused Terminals For use with… Description B-Frame XTPR To cover unused terminals 20 on three-phase commoning link. Protected against 10 direct contact. D-Frame XTPR Pkg. Qty. Catalog Number Price XTPAXUTS XTPAXUTSD Price listed is for a quantity of one (1). Orders must be placed in multiples of package quantity listed. Incoming Terminal Table 186.
XT IEC Power Control Manual Motor Protectors 138 June 2005 Accessories Table 189. Combination Connection Kit Mounting Plate For Use with … Description XTPAXTPCB For mounting of a B-Frame Non-reversing Manual or Combination Motor 4 Controller For mounting of a B-Frame Reversing Manual or Combination Motor 4 Controller XTPAXTPCRB Pkg. Qty. Catalog Number Price XTPAXTPCPB XTPAXTPCRPB Comprised of 45 mm wide adapter plate and connection elements for side-by-side positioning of more plates.
XT IEC Power Control Manual Motor Protectors 139 June 2005 Accessories Table 192.
XT IEC Power Control Manual Motor Protectors 140 June 2005 Accessories Table 195. Insulated Enclosures for Surface Mounting of B-Frame XTPR (0.
XT IEC Power Control Manual Motor Protectors 141 June 2005 Accessories MMP Enclosure Accessories Table 199. XTPR Manual Motor Protector Enclosure Padlock Attachment For Use With… Description Catalog Number Pkg. Qty. XTPAXENCS65B, XTPAXENCS65RY, XTPAXENCSEM65B, XTPAXENCSEM65RY, XTPAXENCS55B, XTPAXENCS55RY, XTPAXENCSEM55B, XTPAXENCSEM55RY XTPAXENCSD65B, XTPAXENCSD65RY XTPAXENCF55B, XTPAXENCF55RY Padlocking feature. Up to 3 padlocks with XTPAXPL1 3 – 6 mm hasp thickness.
142 XT IEC Power Control Manual Motor Protectors June 2005 Technical Data and Specifications Technical Data and Specifications Table 201. XT Manual Motor Protectors — Technical Data and Specifications XTPBP16B – XTPB016B XTPRP16B – XTPR032B XTPR016D – XTPR063D XTPMP16B – XTPM032B XTPTP16B – XTPT025B General Standards IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No.
XT IEC Power Control Manual Motor Protectors 143 June 2005 Technical Data and Specifications Table 201.
144 XT IEC Power Control Manual Motor Protectors June 2005 Technical Data and Specifications Table 203. Undervoltage Release — Technical Data and Specifications Description XTPAXUVR… Cross-sections Table 205. Shunt Release — Technical Data and Specifications Description XTPAXSR __ Cross-sections Solid or flexible conductor with ferrule (mm2) 1 x (0.75 – 2.5) 2 x (0.75 – 2.5) Solid or flexible conductor with ferrule (mm2) 1 x (0.75 – 2.5) 2 x (0.75 – 2.
XT IEC Power Control Manual Motor Protectors 145 June 2005 Technical Data and Specifications Time/Current Curve Minutes Characteristics The time/current characteristic, the current limiting characteristics and the I2t characteristics were determined in accordance with DIN VDE 0660 and IEC 60 947.
XT IEC Power Control Manual Motor Protectors June 2005 Technical Data and Specifications 2 1 0.8 0.6 2.5 A 0.4 0.3 1.6 A 0.2 1A 0.63 A e -w av 6.3 A 4.0 A 4 3 2.5 A 1.5 103 8 6 1.6 A 4 3 0.04 0.03 0.4 A 0.02 Ue = 400 V 1 1.5 2 3 4 0.25 A 6 8 10 15 20 3040 60 80100 cc rms [kA] Figure 78. MMP Let-Through Tripping Characteristics — XTPB, XTPR Frame B, XTPT 100 10 A 2 0.1 0.08 0.06 0.015 0.01 2 1.5 104 8 6 XTPR Frame B 25 A XTPM 20 A 16 A alf cc • 4.
XT IEC Power Control Manual Motor Protectors 147 June 2005 Technical Data and Specifications Manual Motor Protector Short Circuit Ratings Rated uninterrupted current Iu = Rated operational current Ie. Rated conditional short circuit current I q — IEC/EN 60947-4-1. Rated ultimate short circuit breaking capacity I cu — IEC/EN 60947-2. Rated operational short circuit breaking capacity I cs — IEC/EN 60947-2. Table 206.
XT IEC Power Control Manual Motor Protectors 148 June 2005 Technical Data and Specifications Table 207. Ratings for Group Motor Applications — UL 508 / CSA C22.2 No. 14 Catalog Number Rated Uninterrupted Current — Iu (Amps) FLA Adjustment Range / Overload Release — Ir (Amps) Short Circuit Release — Irm (Amps) Maximum Protective Device for UL/CSA Group Protection Max.
XT IEC Power Control Manual Motor Protectors 149 June 2005 Technical Data and Specifications Table 208.
XT IEC Power Control Manual Motor Protectors June 2005 Technical Data and Specifications I> I> I> I> I> I> 2 4 6 2 4 6 Figure 81. XTPB, XTPR 1- and 2-Pole Circuits with DC and AC Current Min. Cross-Section Protected Device 380-415V, 50 Hz, Cu mm2 4 2.5 1.5 1 Type XTPR...B Inherently short-circuit-proof Back-up protection range with XTPAXCL Rated short-circuit breaking capacity range XTPR…B 0.75 50 30 20 16 10 6 0.16... XTPRP16BC1 1016 20 25 Rated Current n [A] Figure 82.
XT IEC Power Control Manual Motor Protectors 151 June 2005 Dimensions Dimensions 93 45 [3.66] [1.77] 93 [3.66] 5.5 [.22] 45 [1.77] 45 [1.77] 44 [1.73] 50 [1.97] 45 [1.77] 74 [2.91] 85 [3.35] 88 [3.46] 94 [3.70] Figure 84. Manual Motor Protectors — XTPB (Approximate Dimensions in mm [in]) Figure 85. Manual Motor Protectors, Manual Transformer Protectors — XTPR…B, XTPT and XTPM (Approximate Dimensions in mm [in]) 4 [.16] 140 [5.57] 65 45 [2.56] 125 [4.92] [1.77] 130 [5.12] 30 [1.18] 7.
152 XT IEC Power Control Manual Motor Protectors June 2005 Dimensions 261 [10.28] (207 [8.15], 153 [6.02], 99 [3.90]) 45 90 [1.77] [3.54] 36 [1.42] 27 [1.06] 54 [2.13] 26 [1.02] 9 [.35] Overlapping Mounting to Extend the Three-Phase Commoning Link 68 [2.68] Figure 89. Standard Auxiliary Contact — XTPAXSA… (Approximate Dimensions in mm [in]) Figure 93. Three-Phase Commoning Link — XTPAXCLKB5, XTPAXCLKB4, XTPAXCLKB3, and XTPAXCLKB2 (Approximate Dimensions in mm [in]) 234 [9.21] (108 [4.
XT IEC Power Control Manual Motor Protectors 153 June 2005 Dimensions 98 [3.86] 158 [6.22] 30 [1.18] Drilling Dimensions 44 [1.73] 30 [1.18] 28 [1.10] 97.5 [3.84] 4.5 [.18] 33 [1.30] 80 [3.15] 97.5 [3.84] 125.5 [4.94] 55 [2.17] 158 [6.22] 153 [6.02] 4.5 [.18] 80 [3.15] Figure 97. Insulated Enclosures for Surface Mounting — XTPAXENCS55…, XTPAXENCSEM… (Approximate Dimensions in mm [in]) 158 [6.22] 158 [6.22] 80 [3.15] 80 [3.15] 116.5 [4.
154 XT IEC Power Control Manual Motor Protectors June 2005 Dimensions 69 [2.72] 69 [2.72] 129 [5.08] 129 [5.08] 90.2 [3.55] 90.2 [3.55] 93 [3.66] 115.2 [4.54] XTPBXENCF… 93 [3.66] 115.2 [4.54] 175.9 [6.93] XTPBXENCFEK55 and XTPBXENCFES55 69 [2.72] 129 [5.08] 90.2 [3.55] 93 [3.66] 115.2 [4.54] XTPBXENCFLE55 and XTPBXENCFLO55 Figure 99. Insulated Enclosures for Flush Mounting — (Approximate Dimensions in mm [in]) 181 160 [7.13] [6.30] 181 160 [7.13] [6.30] 100 [3.94] 100 [3.94] 47.5 [1.
XT IEC Power Control Manual Motor Protectors 155 June 2005 Dimensions 98 [3.86] Drilling Dimensions 30 [1.18] 44 [1.73] 114 [4.49] 30 [1.18] 28 [1.10] M4 33 [1.30] 55 [2.17] 171 [6.73] 181 160 [7.13] [6.30] M4 97 [3.82] Figure 102. Drilling Dimensions —XTPAXENAS55…, XTPAXENASEM55…, XTPAXENCS65…, XTPAXENCSEM65… + XTPAXPL1 (Approximate Dimensions in mm [in]) 43 [1.69] Dia. 64 [2.52] 4 [.16] R 48 [1.89] 116 – 118 [4.57 – 4.64] 64 [2.52] 19.5 [.77] 48 [1.89] 62 [2.44] At least 100 [3.
156 XT IEC Power Control Manual Motor Protectors June 2005 Dimensions 69 [2.72] 129 [5.08] 55 [2.17] 85 [3.35] 80 [3.15] 96 [3.78] 124 [4.88] 98 [3.86] 30 [1.18] 30 [1.18] 28 [1.10] 58 [2.28] 21 [.83] 129 [5.08] 55 [2.17] 85 [3.35] 80 [3.15] 96 [3.78] 124 [4.88] Figure 105. Insulated Enclosures for Flush Mounting — XTPAXENCF…, XTPAXENCF55… + XTPAXPL3 (Approximate Dimensions in mm [in]) 240 [9.45] 160 [6.30] 134 [5.28] 181 [7.13] 197 [7.76] Figure 106.
XT IEC Power Control Manual Motor Protectors 157 June 2005 Dimensions 3 [.12] 98 [3.86] 32 [1.26] 72 [2.83] 5.6 [.22] Dia. 72 [2.83] 240 [9.45] 193 [7.60] 160 [6.30] 186 [7.32] 28 [1.10] 142 [5.60] 30 [1.18] Figure 107. Insulated Enclosures for Surface Mounting — XTPAXENCSD65… + XTPAXPL2, XTPAXENCSD65 (Approximate Dimensions in mm [in]) CAT.02.02.S.K.CD For more information visit: www.EatonElectrical.
158 XT IEC Power Control Manual Motor Protectors June 2005 Dimensions 36 [1.42] 36 [1.42] 205 [8.07] 33 [1.30] 14 [.55] 170 [6.69] 33 [1.30] 14 [.55] Figure 112. Three-Phase Commoning Link — XTPAXCLKB3D (Approximate Dimensions in mm [in]) Figure 108. Three-Phase Commoning Link — XTPAXCLKA4D (Approximate Dimensions in mm [in]) 36 [1.42] 36 [1.42] 14 [.55] 151 [5.94] 33 [1.30] 117 [4.6] 14 [.55] 33 [1.30] Figure 113.
XT IEC Power Control Combination Motor Controllers June 2005 Product Family Overview Application Description Contents Description Standards and Certifications . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . .
XT IEC Power Control Combination Motor Controllers 160 June 2005 Product Family Overview Standards and Certifications Table 209. MMC and CMC Applications UL 508 Type F Combination Motor Controller XT IEC Manual & Combination Motor Controllers ■ IEC Type 2 Approved per IEC 60947-4-1 ■ UL Listed File No. E218618 ■ CE Mark Group Installation Using the in-panel Main SCPD and an MMC without a factory assembled LSA.
XT IEC Power Control Combination Motor Controllers 161 June 2005 Catalog Number Selection Catalog Number Selection Table 212.
XT IEC Power Control Combination Motor Controllers 162 June 2005 Product Selection Product Selection Table 213.
XT IEC Power Control Combination Motor Controllers 163 June 2005 Product Selection Table 214.
XT IEC Power Control Combination Motor Controllers 164 June 2005 Product Selection Table 215.
XT IEC Power Control Combination Motor Controllers 165 June 2005 Product Selection Table 216.
XT IEC Power Control Combination Motor Controllers 166 June 2005 Product Selection Table 217.
XT IEC Power Control Combination Motor Controllers 167 June 2005 Technical Data and Specifications Technical Data and Specifications Table 218.
168 XT IEC Power Control Combination Motor Controllers — Enclosed Control June 2005 Product Family Overview Contents Description Page Cover Control . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . Modification Codes . . . . . . . . .
XT IEC Power Control Combination Motor Controllers — Enclosed Control June 2005 Product Family Overview Cover Control ■ ■ ■ ■ ■ Table 219. Combination Motor Controller Cover Control Factory Installed Description Cover control for Combination Motor Control Starters uses E22 style (22 mm). Selector switches are maintained with lever operators. Pushbuttons are momentary type with extended pushbutton. The kit includes hardware and connecting wires (where possible).
XT IEC Power Control Combination Motor Controllers — Enclosed Control 170 June 2005 Catalog Number Selection Catalog Number Selection Table 220.
XT IEC Power Control Combination Motor Controllers — Enclosed Control June 2005 Product Selection Product Selection Table 222.
XT IEC Power Control Combination Motor Controllers — Enclosed Control 172 June 2005 Product Selection Table 224.
XT IEC Power Control Combination Motor Controllers — Enclosed Control June 2005 Product Selection Table 226.
174 XT IEC Power Control Combination Motor Controllers — Enclosed Control June 2005 Dimensions Dimensions Enclosure Boxes Box Dimensions Type 1, 3R, 4, 4X, 12 XT Combination Motor Controllers (CMCs) For Box Dimensions, See Enclosed Control Product Guide, PG03300001E. Table 228. Class 76 — Self Protected Starter (CMC) IEC Size (Frame/Amps) Box Number Ship Weight kg [lbs] B – H/up to 32A 5A 6.8 [15] B – H/up to 32A 5P 5.4 [12] J – L/40 – 63A 5A 8.2 [18] J – L/40 – 63A 5P 6.
XT IEC Power Control Reference Data 175 June 2005 Approvals for World Markets Overview The XT line of products is approved for use throughout the world, including the USA and Canada. As such, they can be used without restriction as devices for world markets. The majority of countries permit the import of devices on the manufacturer’s undertaking that they have been constructed in accordance with the pertinent specifications.
XT IEC Power Control Reference Data 176 June 2005 The following are important criteria for selecting switchgear suitable for export: ■ For motor-protective circuit-breakers Use inherently short-circuit proof switches capable of controlling the highest prospective fault levels at the point of installation without the need for back-up protection.
XT IEC Power Control Reference Data 177 June 2005 Shipping Classifications Approvals for North America Germany Germanischer Lloyd (GL) In the USA, the legally established OSHA (Occupational Safety and Health Act) and the NEC (National Electrical Code) require the use of approved devices and systems.
XT IEC Power Control Reference Data 178 June 2005 IEC Utilization Categories Table 232. Used in Technical Data & Formulas Code Descriptions (See also IEC/EN 60947-1; 2.1.18/IEV 441-17-19) A combination of specified requirements relating to the condition in which the switching device or fuse fulfills its purpose and selected to represent a characteristic group of real-life applications.
XT IEC Power Control Reference Data 179 June 2005 Annex A (informative) Table 233.
XT IEC Power Control Reference Data 180 June 2005 Motor Ratings Data Ampere Rating of AC and DC Motors Ampere ratings of motors vary somewhat, depending upon the type of motor. The values given below are for drip-proof, Class B insulated (T Frame) where available, 1.15 service factor, NEMA Design B motors. These values represent an average full load motor current which was calculated from the motor performance data published by several motor manufacturers.
XT IEC Power Control Reference Data 181 June 2005 Single-Phase AC Motors DC Motors Table 430-148. Full-Load Currents in Amperes, Single-Phase Alternating-Current Motors The following values of full-load currents are for motors running at usual speeds and motors with normal torque characteristics.
XT IEC Power Control Reference Data 182 June 2005 Ampacities of Insulated Conductors (Based on 1996 NEC ) Notes to Tables 310-16, 310-18 Table 310-16. Allowable Ampacities of Insulated Conductors Rated 0 – 2000V, 60° – 90°C (140° – 194°F), Not More Than Three Current-Carrying Conductors in Raceway or Cable or Earth (Directly Buried), Based on Ambient Temperature of 30°C (86°F) 1. 120/240V, 3-Wire, Single-Phase Dwelling Services and Feeders.
XT IEC Power Control Reference Data 183 June 2005 Ampacities of Insulated Conductors (Based on 1996 NEC ) — Continued Exception No. 4 Table 310-18.
XT IEC Power Control Reference Data 184 June 2005 Enclosure Ratings The UL, NEMA and IEC organizations (and other international groups) define degrees of protection provided by electrical enclosures with respect to personnel, equipment within the housing and the ingress of water. To comply to UL and IEC specifications, the manufacturers must submit product samples, materials used and other data to an independent testing laboratory before ratings can be claimed.
XT IEC Power Control Reference Data 185 June 2005 Index of Enclosure Ratings — IEC Table 236. 1st Characteristic Numeral Table 237. 2nd Characteristic Numeral Protected against contact and penetration of solid bodies. 0 Not protected. 1 Protection against dripping water. 0 Not protected. 2 1 Protection against solid objects greater than 50 mm. Protection against dripping water when tilted up to 15 degrees. 3 Protection against rain. 2 Protection against solid objects greater than 12 mm.
186 XT IEC Power Control June 2005 For more information visit: www.EatonElectrical.ca CAT.02.02.S.K.