User manual

4. Motion Control Instructions
4-62 DVP-MC operating manual
Master scaling =1, slave scaling = 1, master offset = 0, slave offset = 40
Master Positio
n
Slave Position
100
220
360
60
360
100-60=40
When master scaling = 1, slave scaling = 1, master offset = 0, slave offset = 40, slave position
is that in the original cam curve plus 40°
Master scaling =1, slave scaling = 1, master offset = 200, slave offset = 0
Master Position
180
360
60
360
Slave Position
200
When master scaling = 1, slave scaling = 1, master offset = 200, slave offset = 0, slave
position shifts 200 corresponding to the master position. When master position is 0, slave
position is the 180 corresponding to the master position 200 in the original cam curve.