Appendix B Accessories|VFD-S Series
B-18 Revision August 2006, SE08, SW V2.61
B.7 Remote Controller RC-01
(Dimensions are in millimeter)
AFMGND +10VAVI GND
M2
M0 M1 M3
86
5
41615141311
RC-01
Termina l
block
(Wiring
connections)
VFD-S
I/O
Bloc
k
VFD-S Programming
Pr. 2-00 and Pr. 2-01 set to d01
Pr. 4-04 set to d02 (M0, M1 set at RUN/STOP and FWD/REV)
Pr. 4-05 set to d06 (M2 set for reset)
Pr. 4-06 set to d10 (M3 set for jog operation)