Appendix B Accessories|VFD-S Series
B-16 Revision August 2006, SE08, SW V2.61
B.5 Zero Phase Reactor (RF220X00A)
Dimensions are in millimeter and (inch)
Motor
HP kW
Qty.
Recommended Wire Size
(mm
2
)
1/4 0.2
1/2 0.4
1 0.75
2 1.5
0.5 - 5.5
115V/230VSeri
es
3 2.2
1
3.5 - 5.5
1/4 0.2
1/2 0.4
1 0.75
2 1.5
460V
Series
3 2.2
1 0.5 - 5.5
Wiring Method
Please wind each wire 4 times around the core. The reactor must be put at inverter output as close
as possible.
Power
Supply
Zero Phase Reactor
MOTOR
U/T1
V/T2
W/T3
R/L1
S/L2
T/L3