User Manual

v1.0.3
25
6 Specifications
Model
AC MAX Basic
Input
3.7 kW / 11 kW
7.4 kW / 22 kW
Nominal Current
16 A
32 A
Grid Connection
Single
-
phase electric power (L1, N, PE)
Three-phase electric power (L1, L2, L3, N, PE)
All AC MAX BASIC models support both, single phase and three phase
installations
AC Voltage
230 V / 400 V
Frequency
50 Hz /
60 Hz
Grounding systems
TN, TT, IT
Terminal PCB terminal block
Protection Over current, Under voltage, Over voltage, Over temperature, Surge
protection, Short circuit, Ground fault
Standby Power
3.6 W
Charging Output
Nominal Power
Single
-
phase: 3.7
kW
Three-phase: 11 kW
Single
-
phase: 7.4 kW
Three-phase: 22 kW
Nominal Current 16 A per phase 32 A per phase
Connector Type
AC Type 2 Plug
AC Type 2 Plug
AC Type 2 Socket
AC Type 2S Socket
Charging Voltage
230 V / 400 V
Cable Length
5 m (models with AC
Type 2 Plug charging interface)
Protection
RCD Type A (AC 30 mA)
RDC-DD (DC 6 mA)
Compliance
IEC 61851
-
1, IEC 62196
-
2, IEC61008
-
1, IEC 62955
User Interface
Display
Status LED, 4 colors
Authentication Key switch
Charger Configuration Maximum charging current selectable by 8-step hardware DIP switch
Network Interface
Bluetooth
Protocols and Applications
Configuration, control, monitoring and firmware update
RS485
Protocols and Applications
ModBus RTU for energy management
Mechanical Properties
Ingress Protection (IEC 60529) IP55
Impact Protection (IEC 62262)
IK09
Cooling
Natural convection
Dimensions* (W x H x D)
218 x 371 x 167 mm ( 8.6 x 14.6 x 6.6 inch)
Weight* 6.0 kg (13.3 lbs), including charging cable
Environmental Conditions
Operating Temperature Range
-
30 ºC to + 50 ºC (
-
22 ºF to + 122 ºF)
Storage Temperature Range
-
40 ºC to + 80 ºC (
-
40 ºF to + 176 ºF)
Humidity
< 95 % relative humidity, non
-
condensing
Altitude
Up to 2,000 m (6,500 ft.)
Compliance
EU Low Voltage Directive IEC 61851-1, IEC 62479
EU EMI Directive
EN 61000
-
3
-
11 /
-
12, IEC 61851
-
21
-
2