User Manual

v1.0.3
23
Yellow Ready to charge (connecting to EV).
Blue, slow flashing Charging in progress.
Green Charging process completed.
Yellow, slow flashing
Limited output power by active power control, firmware upgrade or log
download.
Red, slow flashing Refer to fault event.
Red Failed self-test or general malfunction.
4.1 Fault events
Status Description Action
Red, 1 Flash
High/under voltage
protection
The EVSE will be auto-recovery once the voltage is
normal. If not, please restart the EVSE or contact
customer support.
Red, 2 Flashes
Residual Current Device
(RCD) tripped
1. Turn off the charger (open the circuit breaker)
2. disconnect the car
3. Check the charging cable and all other compontents
for isolation damages.
4. If no isolation issues are visible, turn on the charger
again by closing the circuit breaker.
Red, 3 Flashes
Ground does not correctly
connect to the EVSE.
1. Check if ground (PE) is well connected.
2. Ensure the wallbox runs Firmware version 5.1 or
higher by using the AC MAX App.
Red, 4 Flashes
Over current protection. Unplug the vehicle connector and plug it again.
Red, 5 Flashes
Over temperature
protection.
Wait for recovery and check if any heat source around
the EVSE. If yes, please try to remove the heat source.
Red, 6 Flashes
Input mis-wired. Swap the Line (L) and Neutral (N).
Red, 7 Flashes
Control pilot signal error,
Gun lock error/fault
Unplug the vehicle connector and plug it again. If not
recovery, please contact customer support.