3. Remove the screw located at the middle cover by using a
Torx T20 screwdriver.
4. Remove the middle cover.
2.2.2 Mark drill holes
The EVSE is a stationary wall-mounted equipment. Using the
template to mark the screw locations for the mounting bracket
and cable holder (optional).
2.2.3 Secure mounting bracket
1. The cable holder is optional and depicted in the figure for
demonstration purposes. The following are
recommended bolt types:
Masonry walls: 1/4" expansion bolts.
Torque: 8.8 N·m (78 lb·in)
Finished walls supported by wood studs: #8 wood
screws of 2" or above screw length.
Torque: 3 N·m (26 lb·in)